BIONIKA LG, Multi-unit abutment, straight with through screw, positioned
BIONIKA LG, Multi-unit abutment, straight with through screw, positioned
SKU:558.396.030.005UDI: 5993220606884 This product bears the CE mark – open the conformity information
Available to order (min. 10 pcs) · Production time: 3–5 working days
Diameter: Ø 3 mm
Couldn't load pickup availability
Brand characteristics
The BIONIKA LG implant system is compatible with the Implant Direct® Legacy® platform and features a refined conical and hexagonal (Cone & Hex) connection that ensures precise fitting and micromovement-free load transfer.
The 22° cone angle directs forces deep into the implant body, reducing cortical bone stress and promoting long-term stability.
The spirally micro-grooved, self-locking thread profile provides strong primary anchorage, while the self-compressing, self-cutting thread design delivers excellent stability even in spongy bone.
The platform switching design supports the natural adaptation of bone and soft tissues, forming a biological seal around the implant shoulder.
The anatomical root-shaped design with a rounded apex facilitates insertion and the effective dissipation of dynamic loads, making the LG system a reliable, aesthetic, and long-term stable solution in clinical practice.
Geometry characteristics
Version: narrow
Narrow Profile, Indexed Multi-Unit Abutment for Transversal Screw Retained Restorations
The Multi-unit abutment, straight with through screw, positioned, narrow is a prosthetic adapter designed to connect to an implant or a multi-unit base, primarily intended for bridge restorations or full-arch, screw-retained prosthetics. Its straight and narrow design makes it particularly advantageous in areas with limited space or in the aesthetic zone, where both function and appearance are critical.
The indexed design ensures that the abutment always reconnects in the same orientation to the multi-unit interface. This enables precise repositioning of prosthetic components and enhances the reliability of the fit—especially important in multi-unit bridges or full-arch restorations. The transversal screw retention allows the final prosthesis to be screw-retained without the need for cement.
Main Advantages:
- Narrow profile: Ideal for tight interproximal spaces and aesthetic zones.
- Straight design: Balanced insertion path and easy assembly.
- Indexed connection: Ensures precise and repeatable orientation.
- Transversal screw retention: For screw-retained, cement-free final prostheses.
- Compatible with multi-unit systems: Provides a stable and reliable prosthetic interface.
- Biocompatible titanium: Sterilizable, long-term use, and tissue-friendly material.
- The product includes the fixation screw.
Indications:
The Multi-unit abutment, straight with through screw, positioned, narrow is the ideal solution for screw-retained bridge restorations supported by multiple implants, where a narrow profile, accurate fit, and repeatable orientation are essential.
Version: wide
Straight, Wide Multi-Unit Abutment with Indexed Orientation for Screw-Retained Restorations
The Multi-unit abutment, straight with through screw, positioned, wide is a prosthetic component designed to connect to an implant-level or intermediate multi-unit interface. It is developed for screw-retained full or partial restorations. The wide profile provides enhanced stability and superior support for extensive crowns, bridges, and full-arch restorations, especially in posterior regions.
The indexed design ensures the abutment consistently returns to the same orientation upon each reconnection, which is essential for achieving precise prosthetic fit, aesthetic alignment, and functional accuracy. The transversal screw-retained design enables cement-free fixation, facilitating easy removal and maintenance of the restoration.
Main Advantages:
- Wide profile: Increased stability and support for larger prosthetic structures.
- Straight geometry: Balanced insertion path when angulation correction is not required.
- Indexed orientation: Reliable, repeatable positioning during each intervention.
- Transversal screw-retained design: Cement-free restorations with retrievability.
- Multi-unit compatibility: Engineered for secure integration within the system.
- Biocompatible titanium: Durable, sterilizable, and tissue-friendly material suitable for long-term clinical use.
- The product includes the fixation screw.
Indications:
The Multi-unit abutment, straight with through screw, positioned, wide is ideal for full-arch or extensive screw-retained restorations where enhanced stability, accurate orientation, and convenient access for maintenance are required — especially in posterior zones.
Version: LT2.7, narrow
Straight, Narrow Multi-Unit Abutment with LT2.7 Connection for Transversal Screw Retained Restorations
The Multi-unit abutment, straight with through screw, positioned, narrow, LT2.7 is a prosthetic component designed for implant-level or intermediate multi-unit interfaces, developed specifically for screw-retained multi-unit restorations. Its narrow profile makes it ideal for limited anatomical spaces or anterior regions where aesthetics and precise fit are essential.
The indexed configuration ensures that the abutment reconnects in the exact same orientation every time, allowing for accurate alignment of prosthetic components. The transversal screw design enables cement-free retention of the final restoration, facilitating easy retrievability and clinical maintenance when necessary. The LT2.7 designation refers to the specific connection geometry compatible with the intended implant system.
Main Advantages:
- LT2.7 connection: System-specific interface for optimal compatibility.
- Narrow design: Optimized for tight spaces and aesthetic zones.
- Straight alignment: Ideal when no angulation correction is needed.
- Indexed orientation: Repeatable and precise repositioning for component alignment.
- Transversal screw-retained design: Cement-free option with improved retrievability.
- Biocompatible titanium: Durable, sterilizable, and clinically proven material.
- The product includes the fixation screw.
Indications:
The Multi-unit abutment, straight with through screw, positioned, narrow, LT2.7 is an excellent solution for screw-retained restorations supported by multiple implants—especially where space constraints, precise orientation, and compatibility with the LT2.7 system are essential.
Version: LT2.7, wide
Straight, Wide Multi-Unit Abutment with LT2.7 Connection for Screw-Retained Restorations
The Multi-unit abutment, straight with through screw, positioned, wide, LT2.7 is a prosthetic adapter designed for implant-level or intermediate multi-unit interfaces. It is intended for screw-retained multi-unit restorations, particularly in posterior regions or when supporting larger prosthetic crowns. The wide profile provides enhanced soft tissue support and stability for the prosthetic superstructure.
The indexed connection ensures consistent orientation upon each reconnection, allowing for precise fit and reliable prosthetic alignment. The transversal screw-retained design offers cement-free fixation of the final restoration, facilitating easy retrievability and long-term maintenance. The LT2.7 connection ensures full compatibility with the specified system.
Main Advantages:
- Wide profile: Enhanced stability and support for larger prosthetic restorations.
- LT2.7 connection: System-specific interface ensuring optimal compatibility.
- Straight geometry: Ideal when implant angulation is aligned with prosthetic needs.
- Indexed engagement: Consistent and repeatable orientation with each placement.
- Transversal screw-retained design: Cement-free fixation for easier retrievability.
- Biocompatible titanium: Durable, sterilizable, and clinically proven material.
- The product includes the fixation screw.
Indications:
The Multi-unit abutment, straight with through screw, positioned, wide, LT2.7 is ideal for screw-retained bridge or full-arch restorations supported by multiple implants—especially in posterior regions where enhanced stability, precise fit, and LT2.7 system compatibility are essential.
The product image is for illustration purposes only; actual colour and geometry may vary depending on selected specifications.
Share