BIONIKA CORTILOG PCL, Multi-unit abutment, straight with through screw, positioned
BIONIKA CORTILOG PCL, Multi-unit abutment, straight with through screw, positioned
SKU:519.397.033.005UDI: 5993221382770 This product bears the CE mark – open the conformity information
Available to order (min. 10 pcs) · Production time: 3–5 working days
Couldn't load pickup availability
Brand characteristics
The BIONIKA Cortilog PCL implant system utilises a flat-platform “tube-in-tube” connection with three cam-shaped lobes that ensure a rotation-proof and stable fit between the abutment and the implant.
This precise engagement provides micromovement-free force transmission and long-term biomechanical stability.
Placement at or slightly below the cortical level supports bone preservation and enhances primary stability.
The spirally micro-grooved, self-locking thread structure efficiently distributes functional loads, promoting rapid osseointegration while minimising micromovements.
Its anatomical root-shaped body, self-cutting and bone-condensing thread geometry allow for immediate loading when appropriate, while the rounded implant apex facilitates easy and accurate surgical placement.
The Cortilog PCL system is compatible with the following platform:
- CAMLOG®
It offers a precisely fitting and reliable alternative to leading international implant systems, combining Hungarian precision with advanced engineering expertise.
Geometry characteristics
Version: LT2.7, narrow
Straight, Narrow Multi-Unit Abutment with LT2.7 Connection for Transversal Screw Retained Restorations
The Multi-unit abutment, straight with through screw, positioned, narrow, LT2.7 is a prosthetic component designed for implant-level or intermediate multi-unit interfaces, developed specifically for screw-retained multi-unit restorations. Its narrow profile makes it ideal for limited anatomical spaces or anterior regions where aesthetics and precise fit are essential.
The indexed configuration ensures that the abutment reconnects in the exact same orientation every time, allowing for accurate alignment of prosthetic components. The transversal screw design enables cement-free retention of the final restoration, facilitating easy retrievability and clinical maintenance when necessary. The LT2.7 designation refers to the specific connection geometry compatible with the intended implant system.
Main Advantages:
- LT2.7 connection: System-specific interface for optimal compatibility.
- Narrow design: Optimized for tight spaces and aesthetic zones.
- Straight alignment: Ideal when no angulation correction is needed.
- Indexed orientation: Repeatable and precise repositioning for component alignment.
- Transversal screw-retained design: Cement-free option with improved retrievability.
- Biocompatible titanium: Durable, sterilizable, and clinically proven material.
- The product includes the fixation screw.
Indications:
The Multi-unit abutment, straight with through screw, positioned, narrow, LT2.7 is an excellent solution for screw-retained restorations supported by multiple implants—especially where space constraints, precise orientation, and compatibility with the LT2.7 system are essential.
Version: LT2.7, wide
Straight, Wide Multi-Unit Abutment with LT2.7 Connection for Screw-Retained Restorations
The Multi-unit abutment, straight with through screw, positioned, wide, LT2.7 is a prosthetic adapter designed for implant-level or intermediate multi-unit interfaces. It is intended for screw-retained multi-unit restorations, particularly in posterior regions or when supporting larger prosthetic crowns. The wide profile provides enhanced soft tissue support and stability for the prosthetic superstructure.
The indexed connection ensures consistent orientation upon each reconnection, allowing for precise fit and reliable prosthetic alignment. The transversal screw-retained design offers cement-free fixation of the final restoration, facilitating easy retrievability and long-term maintenance. The LT2.7 connection ensures full compatibility with the specified system.
Main Advantages:
- Wide profile: Enhanced stability and support for larger prosthetic restorations.
- LT2.7 connection: System-specific interface ensuring optimal compatibility.
- Straight geometry: Ideal when implant angulation is aligned with prosthetic needs.
- Indexed engagement: Consistent and repeatable orientation with each placement.
- Transversal screw-retained design: Cement-free fixation for easier retrievability.
- Biocompatible titanium: Durable, sterilizable, and clinically proven material.
- The product includes the fixation screw.
Indications:
The Multi-unit abutment, straight with through screw, positioned, wide, LT2.7 is ideal for screw-retained bridge or full-arch restorations supported by multiple implants—especially in posterior regions where enhanced stability, precise fit, and LT2.7 system compatibility are essential.
The product image is for illustration purposes only; actual colour and geometry may vary depending on selected specifications.
Share