BIONIKA BIOPLANT, Impression coping for closed tray, parallel, positioned
BIONIKA BIOPLANT, Impression coping for closed tray, parallel, positioned
SKU:502.378.325.120
UDI: 5993220090669
Available
Couldn't load pickup availability
Brand characteristics
The BIONIKA Bioplant implant system is based on a classic internal hexagonal connection design, providing excellent primary stability and long-term biomechanical reliability.
Its precise fit and optimized thread structure ensure even load distribution, reducing bone stress and promoting rapid osseointegration.
The implant’s design supports stable soft tissue closure and facilitates highly aesthetic prosthetic outcomes.
The system is compatible with several widely used implant platforms, including:
- Amelo®
- OT Medical®
- Pitt-Easy®
- Symplant®
The Bioplant offers a dependable and versatile solution for both aesthetic and functional restorative treatments.
Geometry characteristics
Parallel-Walled, Indexed Impression Coping for Closed Tray Technique
The Impression coping for closed tray, parallel, positioned is an implant-level component specifically designed for accurate and stable impressions using the closed tray technique. The parallel-walled geometry enhances the fit and stability of the coping within the impression material, minimizing movement and distortion during removal. This shape is particularly advantageous when high retention and minimal deviation are clinical priorities.
The indexed design ensures that the coping is always repositioned in the exact same predefined orientation on the implant, enabling the precise transfer of spatial positioning to the dental laboratory. This feature is essential in multi-implant restorations where angular discrepancies between implants must be reliably reproduced.
Main Advantages:
- Parallel geometry: Straight walls for enhanced stability and precise fit within the impression material.
- Closed tray compatibility: Easier clinical procedure without removing the coping from the impression tray.
- Indexed connection: Fixed orientation for accurate and repeatable placement.
- Implant-level fit: Reliable, stable connection directly to the implant.
- Biocompatible, precision-machined material: Sterilizable and durable for long-term use.
Indications:
The Impression coping for closed tray, parallel, positioned is recommended in all clinical situations requiring highly accurate spatial transfer, particularly in multi-implant restorations with angulated positioning.
The product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.