{"product_id":"wl-impression-coping-for-open-tray-uniform-non-positioned","title":"BIONIKA WL, Impression coping for open tray, uniform, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA WL\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eVITAL WIELAND®\u003c\/strong\u003e platform and features a \u003cstrong\u003eprecise internal conical connection (Conical-Connection)\u003c\/strong\u003e that ensures a \u003cstrong\u003emicromovement-free\u003c\/strong\u003e and \u003cstrong\u003ebacteria-tight fit\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe implant’s \u003cstrong\u003eanatomical, root-shaped body\u003c\/strong\u003e and \u003cstrong\u003eself-compressing thread profile\u003c\/strong\u003e provide \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e, making the system suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003emicro-grooved cervical zone\u003c\/strong\u003e promotes \u003cstrong\u003ebone preservation\u003c\/strong\u003e and \u003cstrong\u003esoft tissue stabilisation\u003c\/strong\u003e, while the \u003cstrong\u003eself-cutting thread design\u003c\/strong\u003e allows for \u003cstrong\u003egentle insertion\u003c\/strong\u003e and rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e concept minimises \u003cstrong\u003ebone resorption\u003c\/strong\u003e and contributes to \u003cstrong\u003elong-term aesthetic results\u003c\/strong\u003e. The \u003cstrong\u003eBIONIKA WL\u003c\/strong\u003e system is an ideal choice for professionals seeking \u003cstrong\u003ereliable\u003c\/strong\u003e and \u003cstrong\u003eprecise implant solutions\u003c\/strong\u003e compatible with the \u003cstrong\u003eVITAL WIELAND platform\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUniform Design Impression Coping for Open Tray Technique with Flexible Insertion\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is an implant-level component designed for \u003cstrong\u003eopen tray impression techniques\u003c\/strong\u003e. Its \u003cstrong\u003euniform geometry\u003c\/strong\u003e ensures even distribution of the impression material, reducing the risk of distortion and providing a highly accurate and easily reproducible impression.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003enon-positioned design\u003c\/strong\u003e allows for free rotational adjustment during insertion, making the clinical workflow faster and more flexible, especially when rotational indexing is not required. The open tray technique provides precise spatial data on the implant's position, which is essential for accurate prosthetic fabrication.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUniform geometry:\u003c\/strong\u003e Consistent shape for optimal impression material flow and accuracy.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor open tray technique:\u003c\/strong\u003e Precise impression taking via direct screw access and removal.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-positioned design:\u003c\/strong\u003e Freely rotatable for quick and flexible clinical application.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level connection:\u003c\/strong\u003e Secure and reliable fit to the implant interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible material:\u003c\/strong\u003e Sterilisable, durable, and precisely machined.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is ideal for implant-level impressions in cases where rotational orientation is not required, but accurate spatial positioning is critical.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (yellow) \/ L 10 mm","offer_id":58191058075993,"sku":"544.364.035.100","price":53.52,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm (yellow) \/ L 14 mm","offer_id":58191058108761,"sku":"544.364.035.140","price":53.52,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.3 mm (purple) \/ L 10 mm","offer_id":58191058141529,"sku":"544.364.043.100","price":53.52,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.3 mm (purple) \/ L 14 mm","offer_id":58191058174297,"sku":"544.364.043.140","price":53.52,"currency_code":"EUR","in_stock":true},{"title":"Ø 5 mm (blue) \/ L 10 mm","offer_id":58191058207065,"sku":"544.364.050.100","price":53.52,"currency_code":"EUR","in_stock":true},{"title":"Ø 5 mm (blue) \/ L 14 mm","offer_id":58191058239833,"sku":"544.364.050.140","price":53.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_nyitott_kanalhoz_931a0ddf-f982-41e7-a635-9a1767393a5d.jpg?v=1780404302","url":"https:\/\/shop.en.bionika.hu\/products\/wl-impression-coping-for-open-tray-uniform-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}