{"product_id":"wl-implant-driver-mechanical-lamellar-4lt-2-77","title":"BIONIKA WL, Implant driver, mechanical, lamellar, 4LT 2,77","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA WL\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eVITAL WIELAND®\u003c\/strong\u003e platform and features a \u003cstrong\u003eprecise internal conical connection (Conical-Connection)\u003c\/strong\u003e that ensures a \u003cstrong\u003emicromovement-free\u003c\/strong\u003e and \u003cstrong\u003ebacteria-tight fit\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe implant’s \u003cstrong\u003eanatomical, root-shaped body\u003c\/strong\u003e and \u003cstrong\u003eself-compressing thread profile\u003c\/strong\u003e provide \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e, making the system suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003emicro-grooved cervical zone\u003c\/strong\u003e promotes \u003cstrong\u003ebone preservation\u003c\/strong\u003e and \u003cstrong\u003esoft tissue stabilisation\u003c\/strong\u003e, while the \u003cstrong\u003eself-cutting thread design\u003c\/strong\u003e allows for \u003cstrong\u003egentle insertion\u003c\/strong\u003e and rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e concept minimises \u003cstrong\u003ebone resorption\u003c\/strong\u003e and contributes to \u003cstrong\u003elong-term aesthetic results\u003c\/strong\u003e. The \u003cstrong\u003eBIONIKA WL\u003c\/strong\u003e system is an ideal choice for professionals seeking \u003cstrong\u003ereliable\u003c\/strong\u003e and \u003cstrong\u003eprecise implant solutions\u003c\/strong\u003e compatible with the \u003cstrong\u003eVITAL WIELAND platform\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMotor-driven implant driver with grooved 4Lt 2.77 mm connection for precise surgical placement\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImplant driver, mechanical, lamellar, 4LT 2,77\u003c\/strong\u003e is a \u003cstrong\u003ehigh-precision surgical instrument\u003c\/strong\u003e developed specifically for motor-driven implant placement procedures. The \u003cstrong\u003egrooved design\u003c\/strong\u003e combined with the \u003cstrong\u003e4Lt 2.77 mm connection\u003c\/strong\u003e ensures perfect compatibility with the designated implant system, allowing for secure torque transfer and stable positioning throughout the insertion process.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe driver connects to a \u003cstrong\u003esurgical motor\u003c\/strong\u003e and enables controlled, axial insertion of the implant. Made of \u003cstrong\u003esterilisable, medical-grade stainless steel\u003c\/strong\u003e, this tool is reusable, corrosion-resistant, and delivers long-term clinical reliability. The grooved geometry is optimised for implant types requiring this specific internal connection.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eGrooved design:\u003c\/strong\u003e Provides excellent stability for specific implant types.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003e4Lt 2.77 mm connection:\u003c\/strong\u003e System-specific fit ensures guaranteed compatibility.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eMotor-driven operation:\u003c\/strong\u003e Attaches to surgical motors for precise implant insertion.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eMedical-grade steel construction:\u003c\/strong\u003e Sterilisable, reusable, and corrosion-resistant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClinical reliability:\u003c\/strong\u003e Designed for fast, accurate, and safe implant placement.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication area:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImplant driver, mechanical, lamellar, 4LT 2,77\u003c\/strong\u003e is the ideal solution for surgical procedures involving implants with a grooved internal connection, especially when using systems that require the 4Lt 2.77 mm geometry. It ensures quick and reliable torque transmission during the implantation process.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only. Colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (yellow) \/ L 6 mm","offer_id":58191112405337,"sku":"544.195.035.060","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm (yellow) \/ L 12 mm","offer_id":58191112438105,"sku":"544.195.035.120","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm (yellow) \/ L 18 mm","offer_id":58191112470873,"sku":"544.195.035.180","price":44.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/uniform_implantatum_behajto_gepi_lamellas_4lt277_111978cd-b1d7-40ae-9056-f4cf80bfa9ff.jpg?v=1780404499","url":"https:\/\/shop.en.bionika.hu\/products\/wl-implant-driver-mechanical-lamellar-4lt-2-77","provider":"BIONIKA Webshop","version":"1.0","type":"link"}