{"product_id":"tlx-scanbody-screw-retained-non-positioned-narrow","title":"BIONIKA TLX, Scanbody, screw-retained, non-positioned, narrow","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA TLX\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eTIOLOX®\u003c\/strong\u003e platform and features a \u003cstrong\u003eclassic internal hex connection (Internal Hex Connection)\u003c\/strong\u003e, providing a \u003cstrong\u003ereliable\u003c\/strong\u003e, \u003cstrong\u003estable\u003c\/strong\u003e, and \u003cstrong\u003ewell-established fit\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe implant’s \u003cstrong\u003estraight body geometry\u003c\/strong\u003e and \u003cstrong\u003eprecisely engineered thread design\u003c\/strong\u003e ensure excellent \u003cstrong\u003eprimary stability\u003c\/strong\u003e, while the \u003cstrong\u003emicro-grooved neck\u003c\/strong\u003e supports \u003cstrong\u003ebone preservation\u003c\/strong\u003e and long-term \u003cstrong\u003estable integration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eself-cutting thread profile\u003c\/strong\u003e facilitates insertion and optimises \u003cstrong\u003eforce distribution within the bone\u003c\/strong\u003e, minimising stress. The \u003cstrong\u003eanatomically shaped body\u003c\/strong\u003e enhances \u003cstrong\u003ebone compression\u003c\/strong\u003e and promotes rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA TLX\u003c\/strong\u003e system is an ideal choice for professionals working with the \u003cstrong\u003eTIOLOX platform\u003c\/strong\u003e who wish to combine \u003cstrong\u003etraditional design principles\u003c\/strong\u003e with \u003cstrong\u003emodern, precision manufacturing quality\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNarrow non-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned, narrow\u003c\/strong\u003e is an \u003cstrong\u003eimplant-level digital impression component\u003c\/strong\u003e used for the precise planning of CAD\/CAM-based custom restorations. Its \u003cstrong\u003enarrow design\u003c\/strong\u003e allows for use in tight spaces, such as anterior regions or cases with closely positioned implants. The non-indexed configuration offers full freedom to define the restoration’s final orientation during the digital design process.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures stable and accurate connection to the implant or interface, preventing any movement during scanning. The scanbody geometry is compatible with both intraoral and laboratory scanners and supports most open CAD systems, making it an excellent fit for modern digital dental workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNarrow design:\u003c\/strong\u003e Ideal for limited spaces and aesthetic zones.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed version:\u003c\/strong\u003e Flexible orientation during digital planning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Ensures stability and precision throughout the scan.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eOptimised for digital impressions:\u003c\/strong\u003e Suitable for intraoral and laboratory scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatible:\u003c\/strong\u003e Supports contemporary digital design and manufacturing processes.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned, narrow\u003c\/strong\u003e is the ideal choice for digital implant-level impressions, especially in clinical situations with limited space where restoration orientation is to be defined during the digital design phase.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (gray) \/ L 10 mm","offer_id":58652339863897,"sku":"541.495.035.100","price":65.76,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.5 mm (gray) \/ L 10 mm","offer_id":58652339896665,"sku":"541.495.045.100","price":65.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_d29c96d3-ad59-4866-b7c2-c5e51118ee6e.jpg?v=1784706740","url":"https:\/\/shop.en.bionika.hu\/products\/tlx-scanbody-screw-retained-non-positioned-narrow","provider":"BIONIKA Webshop","version":"1.0","type":"link"}