{"product_id":"tlx-implant-analog-for-digital-scan","title":"BIONIKA TLX, Implant analog for digital scan","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA TLX\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eTIOLOX®\u003c\/strong\u003e platform and features a \u003cstrong\u003eclassic internal hex connection (Internal Hex Connection)\u003c\/strong\u003e, providing a \u003cstrong\u003ereliable\u003c\/strong\u003e, \u003cstrong\u003estable\u003c\/strong\u003e, and \u003cstrong\u003ewell-established fit\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe implant’s \u003cstrong\u003estraight body geometry\u003c\/strong\u003e and \u003cstrong\u003eprecisely engineered thread design\u003c\/strong\u003e ensure excellent \u003cstrong\u003eprimary stability\u003c\/strong\u003e, while the \u003cstrong\u003emicro-grooved neck\u003c\/strong\u003e supports \u003cstrong\u003ebone preservation\u003c\/strong\u003e and long-term \u003cstrong\u003estable integration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eself-cutting thread profile\u003c\/strong\u003e facilitates insertion and optimises \u003cstrong\u003eforce distribution within the bone\u003c\/strong\u003e, minimising stress. The \u003cstrong\u003eanatomically shaped body\u003c\/strong\u003e enhances \u003cstrong\u003ebone compression\u003c\/strong\u003e and promotes rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA TLX\u003c\/strong\u003e system is an ideal choice for professionals working with the \u003cstrong\u003eTIOLOX platform\u003c\/strong\u003e who wish to combine \u003cstrong\u003etraditional design principles\u003c\/strong\u003e with \u003cstrong\u003emodern, precision manufacturing quality\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Implant for Digital Impression-Taking and CAD\/CAM Workflows\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImplant analog for digital scan\u003c\/strong\u003e is a specially designed model implant intended for \u003cstrong\u003edigital dental laboratory workflows\u003c\/strong\u003e. It accurately replicates the original implant’s connection geometry, while its surface is \u003cstrong\u003eoptimised for precise detection by both intraoral and laboratory scanners\u003c\/strong\u003e, ensuring distortion-free, high-resolution data capture.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nBased on the digital impression, this model implant enables the \u003cstrong\u003eaccurate design and manufacturing\u003c\/strong\u003e of prosthetic components and restorations using CAD\/CAM technology. It can be securely integrated into printed or moulded models, ensuring accurate spatial position transfer between digital and physical workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eScanner-optimised surface:\u003c\/strong\u003e Excellent visibility for digital scanners, ensuring high-precision scans.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-compatible interface:\u003c\/strong\u003e Precisely replicates the connection geometry of the original implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor digital workflows:\u003c\/strong\u003e Enables full CAD\/CAM integration from design to fabrication.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eStable model fixation:\u003c\/strong\u003e Securely insertable into 3D-printed or conventional models.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImplant analog for digital scan\u003c\/strong\u003e is an ideal solution for any dental laboratory working with digital workflows, where accurate and distortion-free modelling of implant-supported restorations is a critical requirement.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (gray) \/ L 12 mm","offer_id":58652237594969,"sku":"541.527.035.120","price":32.88,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.5 mm (gray) \/ L 12 mm","offer_id":58652237627737,"sku":"541.527.045.120","price":32.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Technikai_implantatum_implant_szintu_csavarral_digitalis_alu_8b3f59d1-e7a4-43ff-9cca-685674aff700.jpg?v=1784706680","url":"https:\/\/shop.en.bionika.hu\/products\/tlx-implant-analog-for-digital-scan","provider":"BIONIKA Webshop","version":"1.0","type":"link"}