{"product_id":"th-scanbody-screw-retained-positioned","title":"BIONIKA TH, Scanbody, screw-retained, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA TH\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eThommen®\u003c\/strong\u003e platform and features an \u003cstrong\u003einternal conical connection (Conical-Connection)\u003c\/strong\u003e with precise alignment, ensuring \u003cstrong\u003emicromovement-free force transmission\u003c\/strong\u003e and \u003cstrong\u003elong-term stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe system utilises a \u003cstrong\u003e24° cone angle\u003c\/strong\u003e that promotes a \u003cstrong\u003ebacteria-tight seal\u003c\/strong\u003e and minimises the risk of \u003cstrong\u003ebone resorption\u003c\/strong\u003e. The \u003cstrong\u003espirally micro-grooved, self-compressing thread profile\u003c\/strong\u003e provides excellent \u003cstrong\u003eprimary stability\u003c\/strong\u003e, while the \u003cstrong\u003eself-cutting design\u003c\/strong\u003e enables simple and controlled insertion.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical, root-shaped body\u003c\/strong\u003e enhances \u003cstrong\u003ebone condensation\u003c\/strong\u003e and supports rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e. The \u003cstrong\u003eBIONIKA TH\u003c\/strong\u003e system is an ideal choice for professionals seeking implant solutions compatible with the \u003cstrong\u003eThommen platform\u003c\/strong\u003e, offering \u003cstrong\u003eprecision\u003c\/strong\u003e, \u003cstrong\u003ebiological stability\u003c\/strong\u003e, and \u003cstrong\u003elong-term reliability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIndexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned\u003c\/strong\u003e is a \u003cstrong\u003eprecision digital impression component\u003c\/strong\u003e designed to capture the exact position and orientation of the implant or interface for CAD\/CAM-based restorations. The \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the scanbody is placed in the same orientation every time, allowing the final prosthetic to be manufactured with accurate alignment.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e provides a secure and stable connection to the implant or abutment, which is critical for maintaining scanning accuracy. The scanbody is suitable for both intraoral and laboratory scanning, and is compatible with most open digital design software systems.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed design:\u003c\/strong\u003e Ensures repeatable, accurate orientation in digital workflows.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Stable and reliable connection during the scanning process.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eHigh scanning precision:\u003c\/strong\u003e Accurate 3D data transfer for final restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatibility:\u003c\/strong\u003e Usable with most open-architecture scanners and software.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEasy handling:\u003c\/strong\u003e Simple placement and removal in both clinical and lab environments.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned\u003c\/strong\u003e is the ideal solution for digital impression workflows where precise orientation of the final restoration is critical — especially in multi-implant cases or prosthetics placed in the aesthetic zone.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (yellow) \/ L 12 mm","offer_id":58191287451993,"sku":"626.496.035.120","price":54.8,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (green) \/ L 12 mm","offer_id":58191287484761,"sku":"626.496.040.120","price":54.8,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.5 mm (blue) \/ L 12 mm","offer_id":58191287517529,"sku":"626.496.045.120","price":54.8,"currency_code":"EUR","in_stock":true},{"title":"Ø 5 mm (gray) \/ L 12 mm","offer_id":58191287550297,"sku":"626.496.050.120","price":54.8,"currency_code":"EUR","in_stock":true},{"title":"Ø 6 mm (purple) \/ L 12 mm","offer_id":58191287583065,"sku":"626.496.060.120","price":54.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_b5bce225-4c8c-4302-a88b-28cf01d02863.jpg?v=1780405403","url":"https:\/\/shop.en.bionika.hu\/products\/th-scanbody-screw-retained-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}