{"product_id":"sv-impression-coping-for-closed-tray-parallel-positioned","title":"BIONIKA SV, Impression coping for closed tray, parallel, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA SV\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eSIC® VANTAGE®\u003c\/strong\u003e platform and features an \u003cstrong\u003einternal conical connection (Conical-Connection)\u003c\/strong\u003e with \u003cstrong\u003ehexagonal positioning\u003c\/strong\u003e, providing a stable, micromovement-free fit.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003econical design\u003c\/strong\u003e optimises force transmission between the implant and the abutment while promoting long-term \u003cstrong\u003ebone and soft tissue stability\u003c\/strong\u003e. The \u003cstrong\u003espirally micro-grooved, self-compressing thread profile\u003c\/strong\u003e ensures high \u003cstrong\u003eprimary stability\u003c\/strong\u003e even in low bone density cases.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e and \u003cstrong\u003eself-cutting thread design\u003c\/strong\u003e facilitate easy insertion, reducing bone stress and promoting rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e. The \u003cstrong\u003eBIONIKA SV\u003c\/strong\u003e system is an ideal choice for professionals working with the \u003cstrong\u003eSIC VANTAGE platform\u003c\/strong\u003e who seek a \u003cstrong\u003eprecise, aesthetic, and long-term stable implant solution\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParallel-Walled, Indexed Impression Coping for Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is an implant-level component specifically designed for accurate and stable impressions using the closed tray technique. The \u003cstrong\u003eparallel-walled geometry\u003c\/strong\u003e enhances the fit and stability of the coping within the impression material, minimizing movement and distortion during removal. This shape is particularly advantageous when high retention and minimal deviation are clinical priorities.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the coping is always repositioned in the exact same predefined orientation on the implant, enabling the precise transfer of spatial positioning to the dental laboratory. This feature is essential in multi-implant restorations where angular discrepancies between implants must be reliably reproduced.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eParallel geometry:\u003c\/strong\u003e Straight walls for enhanced stability and precise fit within the impression material.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatibility:\u003c\/strong\u003e Easier clinical procedure without removing the coping from the impression tray.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed connection:\u003c\/strong\u003e Fixed orientation for accurate and repeatable placement.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Reliable, stable connection directly to the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible, precision-machined material:\u003c\/strong\u003e Sterilizable and durable for long-term use.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is recommended in all clinical situations requiring highly accurate spatial transfer, particularly in multi-implant restorations with angulated positioning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 2.2 mm (gray) \/ L 12 mm","offer_id":58191422128473,"sku":"638.378.022.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 2.5 mm (blue) \/ L 12 mm","offer_id":58191422161241,"sku":"638.378.025.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 2.9 mm (purple) \/ L 12 mm","offer_id":58191422194009,"sku":"638.378.029.120","price":58.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_zart_kanalhoz_parallel_53b43fbb-1c5d-4c2c-9119-2f5f1babbc0c.jpg?v=1780406045","url":"https:\/\/shop.en.bionika.hu\/products\/sv-impression-coping-for-closed-tray-parallel-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}