{"product_id":"si-scanbody-screw-retained-positioned-narrow","title":"BIONIKA SI, Scanbody, screw-retained, positioned, narrow","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA SI\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eSIC® ACE® MAX®\u003c\/strong\u003e platform and utilises a \u003cstrong\u003econical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e, providing excellent \u003cstrong\u003eprimary stability\u003c\/strong\u003e and a micromovement-free fit.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e22° cone angle\u003c\/strong\u003e ensures precise force transmission, while the \u003cstrong\u003edeep-seated connection\u003c\/strong\u003e supports \u003cstrong\u003ebone level preservation\u003c\/strong\u003e and long-term \u003cstrong\u003etissue stability\u003c\/strong\u003e. The implant’s \u003cstrong\u003eanatomical, root-shaped, self-compressing thread design\u003c\/strong\u003e exerts a \u003cstrong\u003ebone-condensing effect\u003c\/strong\u003e, making it ideal for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-cutting thread profile\u003c\/strong\u003e promotes rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e and reduces insertion pressure. The \u003cstrong\u003eBIONIKA SI\u003c\/strong\u003e system is an ideal choice for clinicians seeking a \u003cstrong\u003eprecise and durable implant solution\u003c\/strong\u003e compatible with the \u003cstrong\u003eSIC platform\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompact, indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned, narrow\u003c\/strong\u003e is a \u003cstrong\u003edigital impression component specifically designed for limited spaces\u003c\/strong\u003e, used to capture the precise 3D position of implants or prosthetic interfaces in CAD\/CAM workflows. Its \u003cstrong\u003enarrow profile\u003c\/strong\u003e is especially advantageous in anterior regions or when multiple implants are placed in close proximity. The \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures consistent orientation of the final restoration.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e provides secure and accurate connection during the scanning process, eliminating the risk of displacement or scanning errors. The scanbody geometry is compatible with most open-system intraoral and laboratory scanners, as well as digital design software.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNarrow profile:\u003c\/strong\u003e Ideal for limited space situations and use in the aesthetic zone.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed design:\u003c\/strong\u003e Repeatable orientation for precise restoration alignment.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Ensures stability and reliability during scanning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eOptimised for digital impressions:\u003c\/strong\u003e Suitable for intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatible:\u003c\/strong\u003e Works with most open-architecture design and manufacturing systems.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned, narrow\u003c\/strong\u003e is the ideal choice for digital workflows where space-saving design and precise restoration orientation are essential—particularly in multi-implant cases, anterior restorations, or aesthetic zones.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.3 mm (blue) \/ L 10 mm","offer_id":58200352522585,"sku":"521.497.033.100","price":60.28,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.2 mm (purple) \/ L 10 mm","offer_id":58200352555353,"sku":"521.497.042.100","price":60.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_c55b3e3b-98e7-4456-a786-b8e193e7d6d4.jpg?v=1780484401","url":"https:\/\/shop.en.bionika.hu\/products\/si-scanbody-screw-retained-positioned-narrow","provider":"BIONIKA Webshop","version":"1.0","type":"link"}