{"product_id":"si-scanbody-screw-retained-non-positioned-narrow","title":"BIONIKA SI, Scanbody, screw-retained, non-positioned, narrow","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA SI\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eSIC® ACE® MAX®\u003c\/strong\u003e platform and utilises a \u003cstrong\u003econical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e, providing excellent \u003cstrong\u003eprimary stability\u003c\/strong\u003e and a micromovement-free fit.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e22° cone angle\u003c\/strong\u003e ensures precise force transmission, while the \u003cstrong\u003edeep-seated connection\u003c\/strong\u003e supports \u003cstrong\u003ebone level preservation\u003c\/strong\u003e and long-term \u003cstrong\u003etissue stability\u003c\/strong\u003e. The implant’s \u003cstrong\u003eanatomical, root-shaped, self-compressing thread design\u003c\/strong\u003e exerts a \u003cstrong\u003ebone-condensing effect\u003c\/strong\u003e, making it ideal for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-cutting thread profile\u003c\/strong\u003e promotes rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e and reduces insertion pressure. The \u003cstrong\u003eBIONIKA SI\u003c\/strong\u003e system is an ideal choice for clinicians seeking a \u003cstrong\u003eprecise and durable implant solution\u003c\/strong\u003e compatible with the \u003cstrong\u003eSIC platform\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNarrow non-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned, narrow\u003c\/strong\u003e is an \u003cstrong\u003eimplant-level digital impression component\u003c\/strong\u003e used for the precise planning of CAD\/CAM-based custom restorations. Its \u003cstrong\u003enarrow design\u003c\/strong\u003e allows for use in tight spaces, such as anterior regions or cases with closely positioned implants. The non-indexed configuration offers full freedom to define the restoration’s final orientation during the digital design process.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures stable and accurate connection to the implant or interface, preventing any movement during scanning. The scanbody geometry is compatible with both intraoral and laboratory scanners and supports most open CAD systems, making it an excellent fit for modern digital dental workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNarrow design:\u003c\/strong\u003e Ideal for limited spaces and aesthetic zones.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed version:\u003c\/strong\u003e Flexible orientation during digital planning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Ensures stability and precision throughout the scan.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eOptimised for digital impressions:\u003c\/strong\u003e Suitable for intraoral and laboratory scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatible:\u003c\/strong\u003e Supports contemporary digital design and manufacturing processes.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned, narrow\u003c\/strong\u003e is the ideal choice for digital implant-level impressions, especially in clinical situations with limited space where restoration orientation is to be defined during the digital design phase.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.3 mm (blue) \/ L 10 mm","offer_id":58200350982489,"sku":"521.495.033.100","price":60.28,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.2 mm (purple) \/ L 10 mm","offer_id":58200351015257,"sku":"521.495.042.100","price":60.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_d1744249-8c4a-4ba4-b3af-b864de59b234.jpg?v=1780484397","url":"https:\/\/shop.en.bionika.hu\/products\/si-scanbody-screw-retained-non-positioned-narrow","provider":"BIONIKA Webshop","version":"1.0","type":"link"}