{"product_id":"sgd-tubular-abutment-stepped-implant-level-non-positioned","title":"BIONIKA SGD, Tubular abutment, stepped, implant level, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA SGD\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eSGS® D\u003c\/strong\u003e platform and utilises a \u003cstrong\u003econical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e, providing a stable, micromovement-free fit and efficient load transfer.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe implant’s \u003cstrong\u003etapered, anatomical root-shaped body design\u003c\/strong\u003e enhances \u003cstrong\u003ebone compression\u003c\/strong\u003e and ensures high \u003cstrong\u003eprimary stability\u003c\/strong\u003e across various bone qualities. The \u003cstrong\u003espirally micro-grooved surface\u003c\/strong\u003e improves the bone-to-implant interface, while the \u003cstrong\u003eself-cutting thread\u003c\/strong\u003e facilitates insertion and reduces bone stress.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e technology supports \u003cstrong\u003ebone level preservation\u003c\/strong\u003e and stabilises \u003cstrong\u003esoft tissue closure\u003c\/strong\u003e. The \u003cstrong\u003eBIONIKA SGD\u003c\/strong\u003e system offers a \u003cstrong\u003ereliable, precise, and biologically optimised solution\u003c\/strong\u003e for implant procedures compatible with the \u003cstrong\u003eSGS platform\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eImplant-Level, Non-Indexed Cylindrical Abutment with Stepped Design for Custom Restorations\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003eThe \u003cstrong\u003eTubular abutment, stepped, implant level, non-positioned\u003c\/strong\u003e is a \u003cstrong\u003eprecision prosthetic component\u003c\/strong\u003e that connects directly to the implant and supports the fixation of custom restorations, whether fabricated digitally or using traditional methods. The \u003cstrong\u003estepped design\u003c\/strong\u003e enhances fit and soft tissue support, making it especially beneficial in aesthetically demanding regions.\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003eThe \u003cstrong\u003enon-indexed version\u003c\/strong\u003e allows for free orientation, which is particularly useful in cases where the final direction of the restoration is determined during the laboratory workflow, without the need for a fixed repositioning index. This offers greater flexibility when designing individual crowns or bridges.\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eStepped design:\u003c\/strong\u003e Provides aesthetic benefits and soft tissue support.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed version:\u003c\/strong\u003e Complete freedom in determining restoration orientation.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level connection:\u003c\/strong\u003e Stable fit to the implant platform.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompatible with CAD\/CAM and traditional methods:\u003c\/strong\u003e Flexible use in a range of prosthetic workflows.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible titanium:\u003c\/strong\u003e Durable, sterilisable, and tissue-friendly material.\u003c\/li\u003e\r\n  \u003cli\u003e\u003cstrong\u003eThe screw is included.\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003eThe \u003cstrong\u003eTubular abutment, stepped, implant level, non-positioned\u003c\/strong\u003e is an ideal solution for custom implant-supported restorations where freedom of orientation is prioritised over indexed repositioning, and where adaptation to aesthetic and anatomical requirements is essential during prosthetic design.\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only. The colour and geometry of the product may vary depending on the selected size.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm \/ L 10 mm \/ s 1 mm","offer_id":58191810986329,"sku":"608.779.301.010","price":64.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm \/ L 11 mm \/ s 2 mm","offer_id":58191811019097,"sku":"608.779.301.120","price":64.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm \/ L 12 mm \/ s 3 mm","offer_id":58191811051865,"sku":"608.779.301.230","price":64.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm \/ L 10 mm \/ s 1 mm","offer_id":58191811084633,"sku":"608.779.351.010","price":64.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm \/ L 11 mm \/ s 2 mm","offer_id":58191811117401,"sku":"608.779.351.120","price":64.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm \/ L 12 mm \/ s 3 mm","offer_id":58191811150169,"sku":"608.779.351.230","price":64.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Csofej_PCT_lepcsos_implant_szintu_pozicionalt_643f4ea9-d2d2-4bef-a415-cd135c060c5e.jpg?v=1780407376","url":"https:\/\/shop.en.bionika.hu\/products\/sgd-tubular-abutment-stepped-implant-level-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}