{"product_id":"mo-impression-coping-for-closed-tray-parallel-positioned","title":"BIONIKA MO, Impression coping for closed tray, parallel, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA MO\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eMEGAGEN® AnyOne® platform\u003c\/strong\u003e and features an \u003cstrong\u003einternal conical connection (Conical-Connection)\u003c\/strong\u003e that ensures \u003cstrong\u003emicromovement-free load transfer\u003c\/strong\u003e and \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe precise fit of the \u003cstrong\u003e11° Morse taper\u003c\/strong\u003e minimises microgaps, thereby \u003cstrong\u003eenhancing bone and soft tissue integration\u003c\/strong\u003e and \u003cstrong\u003ereducing the risk of bacterial leakage\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003espirally micro-grooved, self-compressing thread design\u003c\/strong\u003e optimises load distribution and provides \u003cstrong\u003ehigh stability\u003c\/strong\u003e even in softer bone conditions.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, combined with \u003cstrong\u003eself-cutting and bone-condensing threads\u003c\/strong\u003e, allows for \u003cstrong\u003efast and secure insertion\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA MO\u003c\/strong\u003e system is an \u003cstrong\u003eideal choice\u003c\/strong\u003e for \u003cstrong\u003eimmediate implantation and loading cases\u003c\/strong\u003e, where \u003cstrong\u003efunctionality, bone preservation, and aesthetic outcomes\u003c\/strong\u003e are equally essential.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParallel-Walled, Indexed Impression Coping for Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is an implant-level component specifically designed for accurate and stable impressions using the closed tray technique. The \u003cstrong\u003eparallel-walled geometry\u003c\/strong\u003e enhances the fit and stability of the coping within the impression material, minimizing movement and distortion during removal. This shape is particularly advantageous when high retention and minimal deviation are clinical priorities.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the coping is always repositioned in the exact same predefined orientation on the implant, enabling the precise transfer of spatial positioning to the dental laboratory. This feature is essential in multi-implant restorations where angular discrepancies between implants must be reliably reproduced.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eParallel geometry:\u003c\/strong\u003e Straight walls for enhanced stability and precise fit within the impression material.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatibility:\u003c\/strong\u003e Easier clinical procedure without removing the coping from the impression tray.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed connection:\u003c\/strong\u003e Fixed orientation for accurate and repeatable placement.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Reliable, stable connection directly to the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible, precision-machined material:\u003c\/strong\u003e Sterilizable and durable for long-term use.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is recommended in all clinical situations requiring highly accurate spatial transfer, particularly in multi-implant restorations with angulated positioning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 4 mm \/ L 12 mm","offer_id":58199327932761,"sku":"612.378.040.120","price":58.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_zart_kanalhoz_parallel_3244b017-b026-447e-a1ed-99b0e520adad.jpg?v=1780479297","url":"https:\/\/shop.en.bionika.hu\/products\/mo-impression-coping-for-closed-tray-parallel-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}