{"product_id":"lg-scanbody-screw-retained-positioned-narrow","title":"BIONIKA LG, Scanbody, screw-retained, positioned, narrow","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA LG\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eImplant Direct® Legacy® platform\u003c\/strong\u003e and features a \u003cstrong\u003erefined conical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e that ensures \u003cstrong\u003eprecise fitting\u003c\/strong\u003e and \u003cstrong\u003emicromovement-free load transfer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e22° cone angle\u003c\/strong\u003e directs forces deep into the implant body, \u003cstrong\u003ereducing cortical bone stress\u003c\/strong\u003e and \u003cstrong\u003epromoting long-term stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread profile\u003c\/strong\u003e provides \u003cstrong\u003estrong primary anchorage\u003c\/strong\u003e, while the \u003cstrong\u003eself-compressing, self-cutting thread design\u003c\/strong\u003e delivers \u003cstrong\u003eexcellent stability\u003c\/strong\u003e even in spongy bone.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e design supports the \u003cstrong\u003enatural adaptation of bone and soft tissues\u003c\/strong\u003e, forming a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e with a \u003cstrong\u003erounded apex\u003c\/strong\u003e facilitates \u003cstrong\u003einsertion\u003c\/strong\u003e and the \u003cstrong\u003eeffective dissipation of dynamic loads\u003c\/strong\u003e, making the \u003cstrong\u003eLG system\u003c\/strong\u003e a \u003cstrong\u003ereliable, aesthetic, and long-term stable solution\u003c\/strong\u003e in \u003cstrong\u003eclinical practice\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompact, indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned, narrow\u003c\/strong\u003e is a \u003cstrong\u003edigital impression component specifically designed for limited spaces\u003c\/strong\u003e, used to capture the precise 3D position of implants or prosthetic interfaces in CAD\/CAM workflows. Its \u003cstrong\u003enarrow profile\u003c\/strong\u003e is especially advantageous in anterior regions or when multiple implants are placed in close proximity. The \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures consistent orientation of the final restoration.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e provides secure and accurate connection during the scanning process, eliminating the risk of displacement or scanning errors. The scanbody geometry is compatible with most open-system intraoral and laboratory scanners, as well as digital design software.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNarrow profile:\u003c\/strong\u003e Ideal for limited space situations and use in the aesthetic zone.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed design:\u003c\/strong\u003e Repeatable orientation for precise restoration alignment.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Ensures stability and reliability during scanning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eOptimised for digital impressions:\u003c\/strong\u003e Suitable for intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatible:\u003c\/strong\u003e Works with most open-architecture design and manufacturing systems.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned, narrow\u003c\/strong\u003e is the ideal choice for digital workflows where space-saving design and precise restoration orientation are essential—particularly in multi-implant cases, anterior restorations, or aesthetic zones.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm \/ L 10 mm","offer_id":58199553573209,"sku":"558.497.030.100","price":60.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_efce4364-2b6e-4e0b-9ae3-6502d8013f22.jpg?v=1780480796","url":"https:\/\/shop.en.bionika.hu\/products\/lg-scanbody-screw-retained-positioned-narrow","provider":"BIONIKA Webshop","version":"1.0","type":"link"}