{"product_id":"lg-scanbody-screw-retained-non-positioned","title":"BIONIKA LG, Scanbody, screw-retained, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA LG\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eImplant Direct® Legacy® platform\u003c\/strong\u003e and features a \u003cstrong\u003erefined conical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e that ensures \u003cstrong\u003eprecise fitting\u003c\/strong\u003e and \u003cstrong\u003emicromovement-free load transfer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e22° cone angle\u003c\/strong\u003e directs forces deep into the implant body, \u003cstrong\u003ereducing cortical bone stress\u003c\/strong\u003e and \u003cstrong\u003epromoting long-term stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread profile\u003c\/strong\u003e provides \u003cstrong\u003estrong primary anchorage\u003c\/strong\u003e, while the \u003cstrong\u003eself-compressing, self-cutting thread design\u003c\/strong\u003e delivers \u003cstrong\u003eexcellent stability\u003c\/strong\u003e even in spongy bone.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e design supports the \u003cstrong\u003enatural adaptation of bone and soft tissues\u003c\/strong\u003e, forming a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e with a \u003cstrong\u003erounded apex\u003c\/strong\u003e facilitates \u003cstrong\u003einsertion\u003c\/strong\u003e and the \u003cstrong\u003eeffective dissipation of dynamic loads\u003c\/strong\u003e, making the \u003cstrong\u003eLG system\u003c\/strong\u003e a \u003cstrong\u003ereliable, aesthetic, and long-term stable solution\u003c\/strong\u003e in \u003cstrong\u003eclinical practice\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNon-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is a \u003cstrong\u003edevice used for intraoral or laboratory digital impressions\u003c\/strong\u003e, designed to capture the precise implant position and platform geometry for CAD\/CAM workflows. Its non-indexed design allows for flexible use in cases where the final restoration does not require a predetermined orientation or when the orientation is determined during the digital design phase after scanning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures secure and stable fixation to the implant platform or compatible interface, minimising the risk of displacement, inaccurate data capture, or the need for rescan. The scanbody is compatible with most open CAD software systems, facilitating smooth integration into digital workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed design:\u003c\/strong\u003e Flexible application for custom or free-orientation restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw fixation:\u003c\/strong\u003e Secure and reliable connection to the implant or interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor digital impressions:\u003c\/strong\u003e Accurate transmission of 3D position and platform data to CAD\/CAM systems.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Suitable for open-system intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEase of use:\u003c\/strong\u003e Easy insertion and removal without the need for auxiliary tools.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is ideal for digital workflows, especially for implant-level restorations where a predefined orientation is not required and the final alignment is determined during software-based planning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm \/ L 12 mm","offer_id":58199553442137,"sku":"558.494.030.120","price":60.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_ba62523d-367a-42d6-8484-9d726dca5119.jpg?v=1780480788","url":"https:\/\/shop.en.bionika.hu\/products\/lg-scanbody-screw-retained-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}