{"product_id":"lg-impression-coping-for-closed-tray-uniform-positioned","title":"BIONIKA LG, Impression coping for closed tray, uniform, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA LG\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eImplant Direct® Legacy® platform\u003c\/strong\u003e and features a \u003cstrong\u003erefined conical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e that ensures \u003cstrong\u003eprecise fitting\u003c\/strong\u003e and \u003cstrong\u003emicromovement-free load transfer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e22° cone angle\u003c\/strong\u003e directs forces deep into the implant body, \u003cstrong\u003ereducing cortical bone stress\u003c\/strong\u003e and \u003cstrong\u003epromoting long-term stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread profile\u003c\/strong\u003e provides \u003cstrong\u003estrong primary anchorage\u003c\/strong\u003e, while the \u003cstrong\u003eself-compressing, self-cutting thread design\u003c\/strong\u003e delivers \u003cstrong\u003eexcellent stability\u003c\/strong\u003e even in spongy bone.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e design supports the \u003cstrong\u003enatural adaptation of bone and soft tissues\u003c\/strong\u003e, forming a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e with a \u003cstrong\u003erounded apex\u003c\/strong\u003e facilitates \u003cstrong\u003einsertion\u003c\/strong\u003e and the \u003cstrong\u003eeffective dissipation of dynamic loads\u003c\/strong\u003e, making the \u003cstrong\u003eLG system\u003c\/strong\u003e a \u003cstrong\u003ereliable, aesthetic, and long-term stable solution\u003c\/strong\u003e in \u003cstrong\u003eclinical practice\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUniform, Indexed Impression Coping for Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, uniform, positioned\u003c\/strong\u003e is an implant-level component specifically designed for closed tray impression procedures. Its \u003cstrong\u003euniform geometry\u003c\/strong\u003e ensures even distribution of the impression material, reducing the risk of distortion and enhancing the reproducibility of the impression.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eindexed design\u003c\/strong\u003e guarantees that the coping is always repositioned in the exact same orientation on the implant. This enables precise transfer of spatial positioning to the laboratory model, which is particularly important in multi-implant restorations where proper axial alignment is critical.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUniform shape:\u003c\/strong\u003e Consistent geometry promotes accurate material flow and a secure fit.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatible:\u003c\/strong\u003e Simplified, efficient impression-taking without coping removal.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed design:\u003c\/strong\u003e Predefined orientation for reliable repositioning and accuracy.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Stable connection directly to the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible, precision-machined material:\u003c\/strong\u003e Sterilizable and clinically durable.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, uniform, positioned\u003c\/strong\u003e is an ideal solution for multi-implant restorations, especially in cases requiring consistent coping shape and high precision in spatial orientation.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm \/ L 10 mm","offer_id":58199533125977,"sku":"558.381.030.100","price":49.06,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm \/ L 14 mm","offer_id":58199533158745,"sku":"558.381.030.140","price":49.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/uniform_mintaveteli_fej_zart_kanalhoz_uniform_pozicionalt_d8165c36-af33-4948-8ea2-a993bd2853ac.jpg?v=1780480606","url":"https:\/\/shop.en.bionika.hu\/products\/lg-impression-coping-for-closed-tray-uniform-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}