{"product_id":"lg-impression-coping-for-closed-tray-angled-type-b","title":"BIONIKA LG, Impression coping for closed tray, angled, type-B","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA LG\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eImplant Direct® Legacy® platform\u003c\/strong\u003e and features a \u003cstrong\u003erefined conical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e that ensures \u003cstrong\u003eprecise fitting\u003c\/strong\u003e and \u003cstrong\u003emicromovement-free load transfer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e22° cone angle\u003c\/strong\u003e directs forces deep into the implant body, \u003cstrong\u003ereducing cortical bone stress\u003c\/strong\u003e and \u003cstrong\u003epromoting long-term stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread profile\u003c\/strong\u003e provides \u003cstrong\u003estrong primary anchorage\u003c\/strong\u003e, while the \u003cstrong\u003eself-compressing, self-cutting thread design\u003c\/strong\u003e delivers \u003cstrong\u003eexcellent stability\u003c\/strong\u003e even in spongy bone.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e design supports the \u003cstrong\u003enatural adaptation of bone and soft tissues\u003c\/strong\u003e, forming a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e with a \u003cstrong\u003erounded apex\u003c\/strong\u003e facilitates \u003cstrong\u003einsertion\u003c\/strong\u003e and the \u003cstrong\u003eeffective dissipation of dynamic loads\u003c\/strong\u003e, making the \u003cstrong\u003eLG system\u003c\/strong\u003e a \u003cstrong\u003ereliable, aesthetic, and long-term stable solution\u003c\/strong\u003e in \u003cstrong\u003eclinical practice\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAccurate Implant Impression with Angle Correction and Defined Orientation\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, angled, type-B\u003c\/strong\u003e is an implant-level impression component specifically developed for the \u003cstrong\u003eclosed tray technique\u003c\/strong\u003e. Its \u003cstrong\u003eangled design\u003c\/strong\u003e enables angle compensation, making it particularly advantageous when the implant axis deviates from the ideal direction.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eType B positioning\u003c\/strong\u003e ensures that a specific \u003cstrong\u003ecorner\u003c\/strong\u003e of the connecting interface always aligns in the same orientation relative to the top part of the coping. This allows for precise and predictable reproduction during laboratory procedures, which is crucial in multiple-implant restorations where coordinated orientation is essential.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eAngled design:\u003c\/strong\u003e Facilitates angle correction for non-ideally positioned implants.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor closed tray use:\u003c\/strong\u003e Enables impression taking without removing the coping, streamlining clinical workflows.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eType B positioning:\u003c\/strong\u003e A specific corner of the connector is consistently aligned with the coping’s top for repeatable orientation.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level connection:\u003c\/strong\u003e Provides stable, direct engagement with the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible metal:\u003c\/strong\u003e Precisely machined, durable, and sterilisable material for clinical reliability.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, angled, type-B\u003c\/strong\u003e is the optimal choice in clinical situations requiring both angle correction and reliable orientation — particularly in the case of coordinated restorations involving multiple implants.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm \/ L 12 mm \/ 15°","offer_id":58199532175705,"sku":"558.367.301.215","price":79.86,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm \/ L 12 mm \/ 25°","offer_id":58199532208473,"sku":"558.367.301.225","price":79.86,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm \/ L 12 mm \/ 35°","offer_id":58199532241241,"sku":"558.367.301.235","price":79.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_zart_kanalhoz_ferde_15_cd4462d4-0103-4188-a583-52e270649299.jpg?v=1780480589","url":"https:\/\/shop.en.bionika.hu\/products\/lg-impression-coping-for-closed-tray-angled-type-b","provider":"BIONIKA Webshop","version":"1.0","type":"link"}