{"product_id":"implie-scanbody-screw-retained-positioned","title":"BIONIKA IMPLIE, Scanbody, screw-retained, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA IMPLIE\u003c\/strong\u003e implant system utilises a \u003cstrong\u003eCone \u0026amp; Hex connection geometry\u003c\/strong\u003e, ensuring \u003cstrong\u003eprecise, micromovement-free fitting\u003c\/strong\u003e and \u003cstrong\u003estable force transmission\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003e22° easily detachable conical angle\u003c\/strong\u003e allows for \u003cstrong\u003eaccurate alignment\u003c\/strong\u003e and \u003cstrong\u003eoptimal load distribution\u003c\/strong\u003e, while the connection \u003cstrong\u003edirects forces deep within the implant body\u003c\/strong\u003e, \u003cstrong\u003ereducing stress on the cortical zone\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003econical, spirally micro-grooved thread structure\u003c\/strong\u003e engages firmly with the \u003cstrong\u003ecortical layer\u003c\/strong\u003e, while the \u003cstrong\u003ehigh-pitch, self-compressing spongiosa thread\u003c\/strong\u003e provides \u003cstrong\u003erapid bone condensation\u003c\/strong\u003e and \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e and \u003cstrong\u003eself-cutting, self-locking thread profile\u003c\/strong\u003e, the implant is suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003erounded, self-drilling apex\u003c\/strong\u003e facilitates \u003cstrong\u003eprecise insertion\u003c\/strong\u003e and allows \u003cstrong\u003eminor directional adjustments\u003c\/strong\u003e during placement.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA IMPLIE\u003c\/strong\u003e system is compatible with the following implant platforms:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eAlpha Bio® CS\u003c\/li\u003e  \u003cli\u003eAlpha Bio® NICE® CHC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003eprecisely fitting\u003c\/strong\u003e and \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian engineering precision\u003c\/strong\u003e with \u003cstrong\u003elong-term clinical stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIndexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned\u003c\/strong\u003e is a \u003cstrong\u003eprecision digital impression component\u003c\/strong\u003e designed to capture the exact position and orientation of the implant or interface for CAD\/CAM-based restorations. The \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the scanbody is placed in the same orientation every time, allowing the final prosthetic to be manufactured with accurate alignment.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e provides a secure and stable connection to the implant or abutment, which is critical for maintaining scanning accuracy. The scanbody is suitable for both intraoral and laboratory scanning, and is compatible with most open digital design software systems.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed design:\u003c\/strong\u003e Ensures repeatable, accurate orientation in digital workflows.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Stable and reliable connection during the scanning process.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eHigh scanning precision:\u003c\/strong\u003e Accurate 3D data transfer for final restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatibility:\u003c\/strong\u003e Usable with most open-architecture scanners and software.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEasy handling:\u003c\/strong\u003e Simple placement and removal in both clinical and lab environments.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned\u003c\/strong\u003e is the ideal solution for digital impression workflows where precise orientation of the final restoration is critical — especially in multi-implant cases or prosthetics placed in the aesthetic zone.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.2 mm \/ L 12 mm","offer_id":58201709904217,"sku":"647.496.032.120","price":45.6,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.75 mm \/ L 12 mm","offer_id":58201709936985,"sku":"647.496.375.120","price":45.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_3e7c41c5-acb6-4310-adc8-3eb976f40990.jpg?v=1780491150","url":"https:\/\/shop.en.bionika.hu\/products\/implie-scanbody-screw-retained-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}