{"product_id":"implie-scanbody-screw-retained-positioned-narrow","title":"BIONIKA IMPLIE, Scanbody, screw-retained, positioned, narrow","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA IMPLIE\u003c\/strong\u003e implant system utilises a \u003cstrong\u003eCone \u0026amp; Hex connection geometry\u003c\/strong\u003e, ensuring \u003cstrong\u003eprecise, micromovement-free fitting\u003c\/strong\u003e and \u003cstrong\u003estable force transmission\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003e22° easily detachable conical angle\u003c\/strong\u003e allows for \u003cstrong\u003eaccurate alignment\u003c\/strong\u003e and \u003cstrong\u003eoptimal load distribution\u003c\/strong\u003e, while the connection \u003cstrong\u003edirects forces deep within the implant body\u003c\/strong\u003e, \u003cstrong\u003ereducing stress on the cortical zone\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003econical, spirally micro-grooved thread structure\u003c\/strong\u003e engages firmly with the \u003cstrong\u003ecortical layer\u003c\/strong\u003e, while the \u003cstrong\u003ehigh-pitch, self-compressing spongiosa thread\u003c\/strong\u003e provides \u003cstrong\u003erapid bone condensation\u003c\/strong\u003e and \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e and \u003cstrong\u003eself-cutting, self-locking thread profile\u003c\/strong\u003e, the implant is suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003erounded, self-drilling apex\u003c\/strong\u003e facilitates \u003cstrong\u003eprecise insertion\u003c\/strong\u003e and allows \u003cstrong\u003eminor directional adjustments\u003c\/strong\u003e during placement.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA IMPLIE\u003c\/strong\u003e system is compatible with the following implant platforms:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eAlpha Bio® CS\u003c\/li\u003e  \u003cli\u003eAlpha Bio® NICE® CHC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003eprecisely fitting\u003c\/strong\u003e and \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian engineering precision\u003c\/strong\u003e with \u003cstrong\u003elong-term clinical stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompact, indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned, narrow\u003c\/strong\u003e is a \u003cstrong\u003edigital impression component specifically designed for limited spaces\u003c\/strong\u003e, used to capture the precise 3D position of implants or prosthetic interfaces in CAD\/CAM workflows. Its \u003cstrong\u003enarrow profile\u003c\/strong\u003e is especially advantageous in anterior regions or when multiple implants are placed in close proximity. The \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures consistent orientation of the final restoration.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e provides secure and accurate connection during the scanning process, eliminating the risk of displacement or scanning errors. The scanbody geometry is compatible with most open-system intraoral and laboratory scanners, as well as digital design software.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNarrow profile:\u003c\/strong\u003e Ideal for limited space situations and use in the aesthetic zone.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed design:\u003c\/strong\u003e Repeatable orientation for precise restoration alignment.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Ensures stability and reliability during scanning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eOptimised for digital impressions:\u003c\/strong\u003e Suitable for intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatible:\u003c\/strong\u003e Works with most open-architecture design and manufacturing systems.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned, narrow\u003c\/strong\u003e is the ideal choice for digital workflows where space-saving design and precise restoration orientation are essential—particularly in multi-implant cases, anterior restorations, or aesthetic zones.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.2 mm \/ L 10 mm","offer_id":58201710166361,"sku":"647.497.032.100","price":45.6,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.75 mm \/ L 10 mm","offer_id":58201710199129,"sku":"647.497.375.100","price":45.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_e05f9443-0be2-40d3-aa07-f1a8794be04f.jpg?v=1780491152","url":"https:\/\/shop.en.bionika.hu\/products\/implie-scanbody-screw-retained-positioned-narrow","provider":"BIONIKA Webshop","version":"1.0","type":"link"}