{"product_id":"implie-impression-coping-for-closed-tray-uniform-positioned","title":"BIONIKA IMPLIE, Impression coping for closed tray, uniform, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA IMPLIE\u003c\/strong\u003e implant system utilises a \u003cstrong\u003eCone \u0026amp; Hex connection geometry\u003c\/strong\u003e, ensuring \u003cstrong\u003eprecise, micromovement-free fitting\u003c\/strong\u003e and \u003cstrong\u003estable force transmission\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003e22° easily detachable conical angle\u003c\/strong\u003e allows for \u003cstrong\u003eaccurate alignment\u003c\/strong\u003e and \u003cstrong\u003eoptimal load distribution\u003c\/strong\u003e, while the connection \u003cstrong\u003edirects forces deep within the implant body\u003c\/strong\u003e, \u003cstrong\u003ereducing stress on the cortical zone\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003econical, spirally micro-grooved thread structure\u003c\/strong\u003e engages firmly with the \u003cstrong\u003ecortical layer\u003c\/strong\u003e, while the \u003cstrong\u003ehigh-pitch, self-compressing spongiosa thread\u003c\/strong\u003e provides \u003cstrong\u003erapid bone condensation\u003c\/strong\u003e and \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e and \u003cstrong\u003eself-cutting, self-locking thread profile\u003c\/strong\u003e, the implant is suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003erounded, self-drilling apex\u003c\/strong\u003e facilitates \u003cstrong\u003eprecise insertion\u003c\/strong\u003e and allows \u003cstrong\u003eminor directional adjustments\u003c\/strong\u003e during placement.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA IMPLIE\u003c\/strong\u003e system is compatible with the following implant platforms:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eAlpha Bio® CS\u003c\/li\u003e  \u003cli\u003eAlpha Bio® NICE® CHC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003eprecisely fitting\u003c\/strong\u003e and \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian engineering precision\u003c\/strong\u003e with \u003cstrong\u003elong-term clinical stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUniform, Indexed Impression Coping for Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, uniform, positioned\u003c\/strong\u003e is an implant-level component specifically designed for closed tray impression procedures. Its \u003cstrong\u003euniform geometry\u003c\/strong\u003e ensures even distribution of the impression material, reducing the risk of distortion and enhancing the reproducibility of the impression.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eindexed design\u003c\/strong\u003e guarantees that the coping is always repositioned in the exact same orientation on the implant. This enables precise transfer of spatial positioning to the laboratory model, which is particularly important in multi-implant restorations where proper axial alignment is critical.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUniform shape:\u003c\/strong\u003e Consistent geometry promotes accurate material flow and a secure fit.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatible:\u003c\/strong\u003e Simplified, efficient impression-taking without coping removal.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed design:\u003c\/strong\u003e Predefined orientation for reliable repositioning and accuracy.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Stable connection directly to the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible, precision-machined material:\u003c\/strong\u003e Sterilizable and clinically durable.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, uniform, positioned\u003c\/strong\u003e is an ideal solution for multi-implant restorations, especially in cases requiring consistent coping shape and high precision in spatial orientation.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.2 mm \/ L 10 mm","offer_id":58201643647321,"sku":"647.381.032.100","price":37.2,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.2 mm \/ L 14 mm","offer_id":58201643680089,"sku":"647.381.032.140","price":37.2,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.75 mm \/ L 10 mm","offer_id":58201643712857,"sku":"647.381.375.100","price":37.2,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.75 mm \/ L 14 mm","offer_id":58201643745625,"sku":"647.381.375.140","price":37.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/BIONIKA_Implie_Mintaveteli_fej_zart_kanalhoz_mod.jpg?v=1780490937","url":"https:\/\/shop.en.bionika.hu\/products\/implie-impression-coping-for-closed-tray-uniform-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}