{"product_id":"hicon-scanbody-screw-retained-non-positioned","title":"BIONIKA HICON, Scanbody, screw-retained, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA HiCON\u003c\/strong\u003e implant system combines a \u003cstrong\u003eCone, Hex, and Cylinder connection geometry\u003c\/strong\u003e, providing \u003cstrong\u003eprecise, micromovement-free stability\u003c\/strong\u003e through its \u003cstrong\u003e25° easily detachable conical angle\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe accurate fit of the \u003cstrong\u003ecylindrical head extension\u003c\/strong\u003e ensures \u003cstrong\u003eexceptional tilting resistance\u003c\/strong\u003e, while the \u003cstrong\u003edeep internal force distribution\u003c\/strong\u003e reduces \u003cstrong\u003ecortical bone stress\u003c\/strong\u003e and enhances \u003cstrong\u003elong-term load-bearing performance\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e allows natural \u003cstrong\u003ebone growth over the implant shoulder\u003c\/strong\u003e, promoting a \u003cstrong\u003ebiological seal\u003c\/strong\u003e and maintaining \u003cstrong\u003ebone levels\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003econical, spirally micro-grooved cortical surface\u003c\/strong\u003e and \u003cstrong\u003eself-locking, radiused thread structure\u003c\/strong\u003e ensure \u003cstrong\u003eoptimal load distribution\u003c\/strong\u003e, \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e, and \u003cstrong\u003emicromovement-free fixation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003ehigh-pitch self-compressing thread\u003c\/strong\u003e, and \u003cstrong\u003eself-drilling, rounded apex\u003c\/strong\u003e provide \u003cstrong\u003eprecise surgical placement\u003c\/strong\u003e and \u003cstrong\u003eoutstanding primary stability\u003c\/strong\u003e, making it suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eHiCON\u003c\/strong\u003e system is compatible with the \u003cstrong\u003eICX® Templant (TP)\u003c\/strong\u003e platform, offering a \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to premium international implant systems.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNon-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is a \u003cstrong\u003edevice used for intraoral or laboratory digital impressions\u003c\/strong\u003e, designed to capture the precise implant position and platform geometry for CAD\/CAM workflows. Its non-indexed design allows for flexible use in cases where the final restoration does not require a predetermined orientation or when the orientation is determined during the digital design phase after scanning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures secure and stable fixation to the implant platform or compatible interface, minimising the risk of displacement, inaccurate data capture, or the need for rescan. The scanbody is compatible with most open CAD software systems, facilitating smooth integration into digital workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed design:\u003c\/strong\u003e Flexible application for custom or free-orientation restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw fixation:\u003c\/strong\u003e Secure and reliable connection to the implant or interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor digital impressions:\u003c\/strong\u003e Accurate transmission of 3D position and platform data to CAD\/CAM systems.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Suitable for open-system intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEase of use:\u003c\/strong\u003e Easy insertion and removal without the need for auxiliary tools.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is ideal for digital workflows, especially for implant-level restorations where a predefined orientation is not required and the final alignment is determined during software-based planning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm (white) \/ L 12 mm","offer_id":58201602031961,"sku":"561.494.030.120","price":38.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.75 mm (yellow) \/ L 12 mm","offer_id":58201602064729,"sku":"561.494.375.120","price":38.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_bf68396d-bf56-44b7-924a-05eaa6884a3a.jpg?v=1780490703","url":"https:\/\/shop.en.bionika.hu\/products\/hicon-scanbody-screw-retained-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}