{"product_id":"hicon-scanbody-screw-retained-non-positioned-narrow","title":"BIONIKA HICON, Scanbody, screw-retained, non-positioned, narrow","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA HiCON\u003c\/strong\u003e implant system combines a \u003cstrong\u003eCone, Hex, and Cylinder connection geometry\u003c\/strong\u003e, providing \u003cstrong\u003eprecise, micromovement-free stability\u003c\/strong\u003e through its \u003cstrong\u003e25° easily detachable conical angle\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe accurate fit of the \u003cstrong\u003ecylindrical head extension\u003c\/strong\u003e ensures \u003cstrong\u003eexceptional tilting resistance\u003c\/strong\u003e, while the \u003cstrong\u003edeep internal force distribution\u003c\/strong\u003e reduces \u003cstrong\u003ecortical bone stress\u003c\/strong\u003e and enhances \u003cstrong\u003elong-term load-bearing performance\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e allows natural \u003cstrong\u003ebone growth over the implant shoulder\u003c\/strong\u003e, promoting a \u003cstrong\u003ebiological seal\u003c\/strong\u003e and maintaining \u003cstrong\u003ebone levels\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003econical, spirally micro-grooved cortical surface\u003c\/strong\u003e and \u003cstrong\u003eself-locking, radiused thread structure\u003c\/strong\u003e ensure \u003cstrong\u003eoptimal load distribution\u003c\/strong\u003e, \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e, and \u003cstrong\u003emicromovement-free fixation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003ehigh-pitch self-compressing thread\u003c\/strong\u003e, and \u003cstrong\u003eself-drilling, rounded apex\u003c\/strong\u003e provide \u003cstrong\u003eprecise surgical placement\u003c\/strong\u003e and \u003cstrong\u003eoutstanding primary stability\u003c\/strong\u003e, making it suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eHiCON\u003c\/strong\u003e system is compatible with the \u003cstrong\u003eICX® Templant (TP)\u003c\/strong\u003e platform, offering a \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to premium international implant systems.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNarrow non-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned, narrow\u003c\/strong\u003e is an \u003cstrong\u003eimplant-level digital impression component\u003c\/strong\u003e used for the precise planning of CAD\/CAM-based custom restorations. Its \u003cstrong\u003enarrow design\u003c\/strong\u003e allows for use in tight spaces, such as anterior regions or cases with closely positioned implants. The non-indexed configuration offers full freedom to define the restoration’s final orientation during the digital design process.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures stable and accurate connection to the implant or interface, preventing any movement during scanning. The scanbody geometry is compatible with both intraoral and laboratory scanners and supports most open CAD systems, making it an excellent fit for modern digital dental workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNarrow design:\u003c\/strong\u003e Ideal for limited spaces and aesthetic zones.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed version:\u003c\/strong\u003e Flexible orientation during digital planning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Ensures stability and precision throughout the scan.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eOptimised for digital impressions:\u003c\/strong\u003e Suitable for intraoral and laboratory scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatible:\u003c\/strong\u003e Supports contemporary digital design and manufacturing processes.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned, narrow\u003c\/strong\u003e is the ideal choice for digital implant-level impressions, especially in clinical situations with limited space where restoration orientation is to be defined during the digital design phase.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm (white) \/ L 10 mm","offer_id":58201602556249,"sku":"561.495.030.100","price":38.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.75 mm (yellow) \/ L 10 mm","offer_id":58201602589017,"sku":"561.495.375.100","price":38.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_2c0fe340-15cc-41dc-b723-b72093855ded.jpg?v=1780490707","url":"https:\/\/shop.en.bionika.hu\/products\/hicon-scanbody-screw-retained-non-positioned-narrow","provider":"BIONIKA Webshop","version":"1.0","type":"link"}