{"product_id":"hicon-impression-coping-for-open-tray-uniform-non-positioned","title":"BIONIKA HICON, Impression coping for open tray, uniform, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA HiCON\u003c\/strong\u003e implant system combines a \u003cstrong\u003eCone, Hex, and Cylinder connection geometry\u003c\/strong\u003e, providing \u003cstrong\u003eprecise, micromovement-free stability\u003c\/strong\u003e through its \u003cstrong\u003e25° easily detachable conical angle\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe accurate fit of the \u003cstrong\u003ecylindrical head extension\u003c\/strong\u003e ensures \u003cstrong\u003eexceptional tilting resistance\u003c\/strong\u003e, while the \u003cstrong\u003edeep internal force distribution\u003c\/strong\u003e reduces \u003cstrong\u003ecortical bone stress\u003c\/strong\u003e and enhances \u003cstrong\u003elong-term load-bearing performance\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e allows natural \u003cstrong\u003ebone growth over the implant shoulder\u003c\/strong\u003e, promoting a \u003cstrong\u003ebiological seal\u003c\/strong\u003e and maintaining \u003cstrong\u003ebone levels\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003econical, spirally micro-grooved cortical surface\u003c\/strong\u003e and \u003cstrong\u003eself-locking, radiused thread structure\u003c\/strong\u003e ensure \u003cstrong\u003eoptimal load distribution\u003c\/strong\u003e, \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e, and \u003cstrong\u003emicromovement-free fixation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003ehigh-pitch self-compressing thread\u003c\/strong\u003e, and \u003cstrong\u003eself-drilling, rounded apex\u003c\/strong\u003e provide \u003cstrong\u003eprecise surgical placement\u003c\/strong\u003e and \u003cstrong\u003eoutstanding primary stability\u003c\/strong\u003e, making it suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eHiCON\u003c\/strong\u003e system is compatible with the \u003cstrong\u003eICX® Templant (TP)\u003c\/strong\u003e platform, offering a \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to premium international implant systems.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUniform Design Impression Coping for Open Tray Technique with Flexible Insertion\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is an implant-level component designed for \u003cstrong\u003eopen tray impression techniques\u003c\/strong\u003e. Its \u003cstrong\u003euniform geometry\u003c\/strong\u003e ensures even distribution of the impression material, reducing the risk of distortion and providing a highly accurate and easily reproducible impression.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003enon-positioned design\u003c\/strong\u003e allows for free rotational adjustment during insertion, making the clinical workflow faster and more flexible, especially when rotational indexing is not required. The open tray technique provides precise spatial data on the implant's position, which is essential for accurate prosthetic fabrication.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUniform geometry:\u003c\/strong\u003e Consistent shape for optimal impression material flow and accuracy.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor open tray technique:\u003c\/strong\u003e Precise impression taking via direct screw access and removal.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-positioned design:\u003c\/strong\u003e Freely rotatable for quick and flexible clinical application.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level connection:\u003c\/strong\u003e Secure and reliable fit to the implant interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible material:\u003c\/strong\u003e Sterilisable, durable, and precisely machined.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is ideal for implant-level impressions in cases where rotational orientation is not required, but accurate spatial positioning is critical.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm (white) \/ L 10 mm","offer_id":58201547440473,"sku":"561.364.030.100","price":31.2,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm (white) \/ L 14 mm","offer_id":58201547473241,"sku":"561.364.030.140","price":31.2,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.75 mm (yellow) \/ L 10 mm","offer_id":58201547506009,"sku":"561.364.375.100","price":31.2,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.75 mm (yellow) \/ L 14 mm","offer_id":58201547538777,"sku":"561.364.375.140","price":31.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/BIONIKA_Hicon_Mintaveteli_fej_nyitott_kanalhoz_mod.jpg?v=1780490524","url":"https:\/\/shop.en.bionika.hu\/products\/hicon-impression-coping-for-open-tray-uniform-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}