{"product_id":"fp-narrow-abutment-angled-positioned-type-a","title":"BIONIKA FP, Narrow abutment, angled, positioned, type-A","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA FP\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eFullplant® platform\u003c\/strong\u003e and features a \u003cstrong\u003econical and hexagonal (Cone \u0026amp; Hex) connection geometry\u003c\/strong\u003e that ensures \u003cstrong\u003eprecise, micromovement-free fitting\u003c\/strong\u003e and \u003cstrong\u003ebalanced load transfer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e24° cone angle\u003c\/strong\u003e directs forces deep into the implant body, \u003cstrong\u003ereducing bone stress\u003c\/strong\u003e and \u003cstrong\u003eenhancing long-term stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking, and self-compressing thread profile\u003c\/strong\u003e provides \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e, while the \u003cem\u003eplatform switching\u003c\/em\u003e design promotes \u003cstrong\u003enatural adaptation of bone and soft tissues\u003c\/strong\u003e, creating a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped, self-cutting, and bone-condensing thread design\u003c\/strong\u003e allows for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e, ensuring \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e and an \u003cstrong\u003eaesthetic outcome\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA FP system\u003c\/strong\u003e offers a \u003cstrong\u003ereliable solution\u003c\/strong\u003e for \u003cstrong\u003estable, precise, and long-term sustainable implantology applications\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNarrow Angled Abutment for Constrained Spaces with Indexed Orientation\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eNarrow abutment, angled, positioned, type-A\u003c\/strong\u003e is an implant-level restoration component specifically designed for cases requiring \u003cstrong\u003eangulation correction\u003c\/strong\u003e in \u003cstrong\u003enarrow interproximal spaces\u003c\/strong\u003e. Its slim profile is ideal for limited space within the dental arch, while the angled configuration allows for the compensation of suboptimally placed implants.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eType A indexed connection\u003c\/strong\u003e ensures that one specific \u003cstrong\u003eflat surface\u003c\/strong\u003e of the abutment interface always aligns with the same orientation relative to the top of the abutment. This guarantees fixed rotational positioning, which is essential in multi-implant cases—especially when combined with angled abutments. Accurate repositioning enhances the alignment of prosthetic components and contributes to a harmonious soft tissue profile.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eSlender design:\u003c\/strong\u003e Ideal for narrow interdental spaces and limited gingival height.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eAngled correction:\u003c\/strong\u003e Optimises prosthetic axis by compensating for implant misalignment.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed connection (Type A):\u003c\/strong\u003e Ensures consistent orientation—flat face always in the same position.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Direct, stable connection to the implant body.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible titanium:\u003c\/strong\u003e Safe, sterilizable, and durable for long-term clinical use.\u003c\/li\u003e\r\n  \u003cli\u003e\u003cstrong\u003eThe product includes the screw.\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication Area:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eNarrow abutment, angled, positioned, type-A\u003c\/strong\u003e is an excellent solution for anterior regions or tightly spaced implant sites, especially where angular correction and precise prosthetic alignment are required during treatment planning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only. Colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 4 mm (gray) \/ L 9 mm \/ 15°","offer_id":58190884307289,"sku":"577.277.409.015","price":72.6,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (gray) \/ L 9 mm \/ 25°","offer_id":58190884340057,"sku":"577.277.409.025","price":72.6,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (gray) \/ L 9 mm \/ 35°","offer_id":58190884372825,"sku":"577.277.409.035","price":72.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Keskeny_fej_ferde_111fa410-8b93-44d4-bafe-c100cb1d33b8.jpg?v=1780403485","url":"https:\/\/shop.en.bionika.hu\/products\/fp-narrow-abutment-angled-positioned-type-a","provider":"BIONIKA Webshop","version":"1.0","type":"link"}