{"product_id":"fp-impression-coping-for-open-tray-uniform-non-positioned","title":"BIONIKA FP, Impression coping for open tray, uniform, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA FP\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eFullplant® platform\u003c\/strong\u003e and features a \u003cstrong\u003econical and hexagonal (Cone \u0026amp; Hex) connection geometry\u003c\/strong\u003e that ensures \u003cstrong\u003eprecise, micromovement-free fitting\u003c\/strong\u003e and \u003cstrong\u003ebalanced load transfer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e24° cone angle\u003c\/strong\u003e directs forces deep into the implant body, \u003cstrong\u003ereducing bone stress\u003c\/strong\u003e and \u003cstrong\u003eenhancing long-term stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking, and self-compressing thread profile\u003c\/strong\u003e provides \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e, while the \u003cem\u003eplatform switching\u003c\/em\u003e design promotes \u003cstrong\u003enatural adaptation of bone and soft tissues\u003c\/strong\u003e, creating a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eanatomical root-shaped, self-cutting, and bone-condensing thread design\u003c\/strong\u003e allows for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e, ensuring \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e and an \u003cstrong\u003eaesthetic outcome\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA FP system\u003c\/strong\u003e offers a \u003cstrong\u003ereliable solution\u003c\/strong\u003e for \u003cstrong\u003estable, precise, and long-term sustainable implantology applications\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUniform Design Impression Coping for Open Tray Technique with Flexible Insertion\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is an implant-level component designed for \u003cstrong\u003eopen tray impression techniques\u003c\/strong\u003e. Its \u003cstrong\u003euniform geometry\u003c\/strong\u003e ensures even distribution of the impression material, reducing the risk of distortion and providing a highly accurate and easily reproducible impression.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003enon-positioned design\u003c\/strong\u003e allows for free rotational adjustment during insertion, making the clinical workflow faster and more flexible, especially when rotational indexing is not required. The open tray technique provides precise spatial data on the implant's position, which is essential for accurate prosthetic fabrication.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUniform geometry:\u003c\/strong\u003e Consistent shape for optimal impression material flow and accuracy.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor open tray technique:\u003c\/strong\u003e Precise impression taking via direct screw access and removal.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-positioned design:\u003c\/strong\u003e Freely rotatable for quick and flexible clinical application.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level connection:\u003c\/strong\u003e Secure and reliable fit to the implant interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible material:\u003c\/strong\u003e Sterilisable, durable, and precisely machined.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is ideal for implant-level impressions in cases where rotational orientation is not required, but accurate spatial positioning is critical.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 4 mm (gray) \/ L 10 mm","offer_id":58190880473433,"sku":"577.364.040.100","price":44.6,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (gray) \/ L 14 mm","offer_id":58190880506201,"sku":"577.364.040.140","price":44.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_nyitott_kanalhoz_00cef39c-f766-40ac-886d-28f3da2582c2.jpg?v=1780403463","url":"https:\/\/shop.en.bionika.hu\/products\/fp-impression-coping-for-open-tray-uniform-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}