{"product_id":"ecoplant-scanbody-screw-retained-positioned","title":"BIONIKA ECOPLANT, Scanbody, screw-retained, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA ECOplant\u003c\/strong\u003e implant system combines a \u003cstrong\u003eCone, Hex, and Cylinder connection geometry\u003c\/strong\u003e, providing a \u003cstrong\u003eproven, precise, and micromovement-free fit\u003c\/strong\u003e widely recognised in engineering practice.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e30° conical angle\u003c\/strong\u003e ensures \u003cstrong\u003eoptimal force transmission\u003c\/strong\u003e while directing loads \u003cstrong\u003edeep into the implant body\u003c\/strong\u003e, thereby \u003cstrong\u003ereducing stress on the cortical bone\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003ePlacement \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e supports \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e, while the \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e enables \u003cstrong\u003enatural soft-tissue closure\u003c\/strong\u003e, creating a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e and \u003cstrong\u003ecycloid thread profile\u003c\/strong\u003e effectively \u003cstrong\u003edissipate dynamic forces\u003c\/strong\u003e, maintaining \u003cstrong\u003emicromovement-free stability\u003c\/strong\u003e and promoting \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e, \u003cstrong\u003edeep thread profile\u003c\/strong\u003e, and \u003cstrong\u003ebone-condensing geometry\u003c\/strong\u003e, the ECOplant implant ensures \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e and allows for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e when clinically indicated.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003erounded apex\u003c\/strong\u003e facilitates \u003cstrong\u003eprecise surgical placement\u003c\/strong\u003e and \u003cstrong\u003eminimises bone stress\u003c\/strong\u003e during insertion.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIndexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned\u003c\/strong\u003e is a \u003cstrong\u003eprecision digital impression component\u003c\/strong\u003e designed to capture the exact position and orientation of the implant or interface for CAD\/CAM-based restorations. The \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the scanbody is placed in the same orientation every time, allowing the final prosthetic to be manufactured with accurate alignment.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e provides a secure and stable connection to the implant or abutment, which is critical for maintaining scanning accuracy. The scanbody is suitable for both intraoral and laboratory scanning, and is compatible with most open digital design software systems.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed design:\u003c\/strong\u003e Ensures repeatable, accurate orientation in digital workflows.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Stable and reliable connection during the scanning process.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eHigh scanning precision:\u003c\/strong\u003e Accurate 3D data transfer for final restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatibility:\u003c\/strong\u003e Usable with most open-architecture scanners and software.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEasy handling:\u003c\/strong\u003e Simple placement and removal in both clinical and lab environments.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, positioned\u003c\/strong\u003e is the ideal solution for digital impression workflows where precise orientation of the final restoration is critical — especially in multi-implant cases or prosthetics placed in the aesthetic zone.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (gray) \/ L 12 mm","offer_id":58201518604633,"sku":"504.496.035.120","price":43.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_40ef2b23-1b5b-4980-b8a7-2f494a37b1d6.jpg?v=1780490397","url":"https:\/\/shop.en.bionika.hu\/products\/ecoplant-scanbody-screw-retained-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}