{"product_id":"ecoplant-scanbody-screw-retained-non-positioned","title":"BIONIKA ECOPLANT, Scanbody, screw-retained, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA ECOplant\u003c\/strong\u003e implant system combines a \u003cstrong\u003eCone, Hex, and Cylinder connection geometry\u003c\/strong\u003e, providing a \u003cstrong\u003eproven, precise, and micromovement-free fit\u003c\/strong\u003e widely recognised in engineering practice.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e30° conical angle\u003c\/strong\u003e ensures \u003cstrong\u003eoptimal force transmission\u003c\/strong\u003e while directing loads \u003cstrong\u003edeep into the implant body\u003c\/strong\u003e, thereby \u003cstrong\u003ereducing stress on the cortical bone\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003ePlacement \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e supports \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e, while the \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e enables \u003cstrong\u003enatural soft-tissue closure\u003c\/strong\u003e, creating a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e and \u003cstrong\u003ecycloid thread profile\u003c\/strong\u003e effectively \u003cstrong\u003edissipate dynamic forces\u003c\/strong\u003e, maintaining \u003cstrong\u003emicromovement-free stability\u003c\/strong\u003e and promoting \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e, \u003cstrong\u003edeep thread profile\u003c\/strong\u003e, and \u003cstrong\u003ebone-condensing geometry\u003c\/strong\u003e, the ECOplant implant ensures \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e and allows for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e when clinically indicated.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003erounded apex\u003c\/strong\u003e facilitates \u003cstrong\u003eprecise surgical placement\u003c\/strong\u003e and \u003cstrong\u003eminimises bone stress\u003c\/strong\u003e during insertion.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNon-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is a \u003cstrong\u003edevice used for intraoral or laboratory digital impressions\u003c\/strong\u003e, designed to capture the precise implant position and platform geometry for CAD\/CAM workflows. Its non-indexed design allows for flexible use in cases where the final restoration does not require a predetermined orientation or when the orientation is determined during the digital design phase after scanning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures secure and stable fixation to the implant platform or compatible interface, minimising the risk of displacement, inaccurate data capture, or the need for rescan. The scanbody is compatible with most open CAD software systems, facilitating smooth integration into digital workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed design:\u003c\/strong\u003e Flexible application for custom or free-orientation restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw fixation:\u003c\/strong\u003e Secure and reliable connection to the implant or interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor digital impressions:\u003c\/strong\u003e Accurate transmission of 3D position and platform data to CAD\/CAM systems.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Suitable for open-system intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEase of use:\u003c\/strong\u003e Easy insertion and removal without the need for auxiliary tools.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is ideal for digital workflows, especially for implant-level restorations where a predefined orientation is not required and the final alignment is determined during software-based planning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (gray) \/ L 12 mm","offer_id":58201517883737,"sku":"504.494.035.120","price":43.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_4542581d-1d89-47a8-8071-00943afff121.jpg?v=1780490393","url":"https:\/\/shop.en.bionika.hu\/products\/ecoplant-scanbody-screw-retained-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}