{"product_id":"ecoplant-scanbody-screw-retained-non-positioned-narrow","title":"BIONIKA ECOPLANT, Scanbody, screw-retained, non-positioned, narrow","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA ECOplant\u003c\/strong\u003e implant system combines a \u003cstrong\u003eCone, Hex, and Cylinder connection geometry\u003c\/strong\u003e, providing a \u003cstrong\u003eproven, precise, and micromovement-free fit\u003c\/strong\u003e widely recognised in engineering practice.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e30° conical angle\u003c\/strong\u003e ensures \u003cstrong\u003eoptimal force transmission\u003c\/strong\u003e while directing loads \u003cstrong\u003edeep into the implant body\u003c\/strong\u003e, thereby \u003cstrong\u003ereducing stress on the cortical bone\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003ePlacement \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e supports \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e, while the \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e enables \u003cstrong\u003enatural soft-tissue closure\u003c\/strong\u003e, creating a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e and \u003cstrong\u003ecycloid thread profile\u003c\/strong\u003e effectively \u003cstrong\u003edissipate dynamic forces\u003c\/strong\u003e, maintaining \u003cstrong\u003emicromovement-free stability\u003c\/strong\u003e and promoting \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e, \u003cstrong\u003edeep thread profile\u003c\/strong\u003e, and \u003cstrong\u003ebone-condensing geometry\u003c\/strong\u003e, the ECOplant implant ensures \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e and allows for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e when clinically indicated.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003erounded apex\u003c\/strong\u003e facilitates \u003cstrong\u003eprecise surgical placement\u003c\/strong\u003e and \u003cstrong\u003eminimises bone stress\u003c\/strong\u003e during insertion.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNarrow non-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned, narrow\u003c\/strong\u003e is an \u003cstrong\u003eimplant-level digital impression component\u003c\/strong\u003e used for the precise planning of CAD\/CAM-based custom restorations. Its \u003cstrong\u003enarrow design\u003c\/strong\u003e allows for use in tight spaces, such as anterior regions or cases with closely positioned implants. The non-indexed configuration offers full freedom to define the restoration’s final orientation during the digital design process.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures stable and accurate connection to the implant or interface, preventing any movement during scanning. The scanbody geometry is compatible with both intraoral and laboratory scanners and supports most open CAD systems, making it an excellent fit for modern digital dental workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNarrow design:\u003c\/strong\u003e Ideal for limited spaces and aesthetic zones.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed version:\u003c\/strong\u003e Flexible orientation during digital planning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw retention:\u003c\/strong\u003e Ensures stability and precision throughout the scan.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eOptimised for digital impressions:\u003c\/strong\u003e Suitable for intraoral and laboratory scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAD\/CAM compatible:\u003c\/strong\u003e Supports contemporary digital design and manufacturing processes.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned, narrow\u003c\/strong\u003e is the ideal choice for digital implant-level impressions, especially in clinical situations with limited space where restoration orientation is to be defined during the digital design phase.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (gray) \/ L 10 mm","offer_id":58201518178649,"sku":"504.495.035.100","price":43.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_9aa97400-be91-4253-98e4-37d0ea8fa9b2.jpg?v=1780490395","url":"https:\/\/shop.en.bionika.hu\/products\/ecoplant-scanbody-screw-retained-non-positioned-narrow","provider":"BIONIKA Webshop","version":"1.0","type":"link"}