{"product_id":"dn-impression-coping-for-closed-tray-angled-type-b","title":"BIONIKA DN, Impression coping for closed tray, angled, type-B","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA DN\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eDentium® NR Line platform\u003c\/strong\u003e and features a \u003cstrong\u003eprecise conical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e that ensures \u003cstrong\u003emicromovement-free fitting\u003c\/strong\u003e and \u003cstrong\u003estable load transfer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e22° cone angle\u003c\/strong\u003e directs forces deep into the implant body, thereby \u003cstrong\u003eminimising bone stress\u003c\/strong\u003e and enhancing \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e provides excellent \u003cstrong\u003eengagement in the cortical layer\u003c\/strong\u003e, while the \u003cstrong\u003eself-compressing, self-cutting thread profile\u003c\/strong\u003e ensures outstanding \u003cstrong\u003eprimary stability\u003c\/strong\u003e in the spongy bone.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e design supports the \u003cstrong\u003enatural adaptation of soft tissues\u003c\/strong\u003e, creating a \u003cstrong\u003ebiological seal\u003c\/strong\u003e around the implant shoulder.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e, \u003cstrong\u003ebone-condensing thread geometry\u003c\/strong\u003e, and \u003cstrong\u003erounded apex\u003c\/strong\u003e, the \u003cstrong\u003eDN system\u003c\/strong\u003e offers \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e, \u003cstrong\u003eprecise placement\u003c\/strong\u003e, and \u003cstrong\u003elong-term reliability\u003c\/strong\u003e across all clinical indications.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAccurate Implant Impression with Angle Correction and Defined Orientation\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, angled, type-B\u003c\/strong\u003e is an implant-level impression component specifically developed for the \u003cstrong\u003eclosed tray technique\u003c\/strong\u003e. Its \u003cstrong\u003eangled design\u003c\/strong\u003e enables angle compensation, making it particularly advantageous when the implant axis deviates from the ideal direction.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eType B positioning\u003c\/strong\u003e ensures that a specific \u003cstrong\u003ecorner\u003c\/strong\u003e of the connecting interface always aligns in the same orientation relative to the top part of the coping. This allows for precise and predictable reproduction during laboratory procedures, which is crucial in multiple-implant restorations where coordinated orientation is essential.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eAngled design:\u003c\/strong\u003e Facilitates angle correction for non-ideally positioned implants.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor closed tray use:\u003c\/strong\u003e Enables impression taking without removing the coping, streamlining clinical workflows.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eType B positioning:\u003c\/strong\u003e A specific corner of the connector is consistently aligned with the coping’s top for repeatable orientation.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level connection:\u003c\/strong\u003e Provides stable, direct engagement with the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible metal:\u003c\/strong\u003e Precisely machined, durable, and sterilisable material for clinical reliability.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, angled, type-B\u003c\/strong\u003e is the optimal choice in clinical situations requiring both angle correction and reliable orientation — particularly in the case of coordinated restorations involving multiple implants.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.7 mm (gray) \/ L 12 mm \/ 15°","offer_id":58199564648793,"sku":"616.367.371.215","price":65.34,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.7 mm (gray) \/ L 12 mm \/ 25°","offer_id":58199564681561,"sku":"616.367.371.225","price":65.34,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.7 mm (gray) \/ L 12 mm \/ 35°","offer_id":58199564714329,"sku":"616.367.371.235","price":65.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_zart_kanalhoz_ferde_15_12eade0f-c5c8-4589-8dd0-3aaf4fc0abc8.jpg?v=1780480923","url":"https:\/\/shop.en.bionika.hu\/products\/dn-impression-coping-for-closed-tray-angled-type-b","provider":"BIONIKA Webshop","version":"1.0","type":"link"}