{"product_id":"di-uf-scanbody-screw-retained-non-positioned","title":"BIONIKA DI UF, Scanbody, screw-retained, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA DI-UF\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eDIO® UF platform\u003c\/strong\u003e and features an \u003cstrong\u003eadvanced conical connection (Conical-Connection)\u003c\/strong\u003e combined with a \u003cstrong\u003ehexagonal fit\u003c\/strong\u003e, ensuring \u003cstrong\u003emicromovement-free load transfer\u003c\/strong\u003e and \u003cstrong\u003eexceptional stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e22° cone angle\u003c\/strong\u003e directs forces deep into the implant body, \u003cstrong\u003ereducing cortical bone stress\u003c\/strong\u003e and \u003cstrong\u003epromoting long-term osseointegration\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking, and self-compressing thread structure\u003c\/strong\u003e provides \u003cstrong\u003eenhanced primary stability\u003c\/strong\u003e, especially in \u003cstrong\u003esofter bone conditions\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e design supports the \u003cstrong\u003enatural adaptation and biological sealing\u003c\/strong\u003e of soft tissues around the implant shoulder, ensuring an \u003cstrong\u003eaesthetic and hygienic result\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eFollowing the \u003cstrong\u003eanatomical root shape\u003c\/strong\u003e, the \u003cstrong\u003eself-cutting and bone-condensing thread profile\u003c\/strong\u003e, together with the \u003cstrong\u003erounded implant apex\u003c\/strong\u003e, ensures \u003cstrong\u003eoptimal placement\u003c\/strong\u003e and \u003cstrong\u003elong-term, stable osseointegration\u003c\/strong\u003e for the \u003cstrong\u003eDI-UF system\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNon-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is a \u003cstrong\u003edevice used for intraoral or laboratory digital impressions\u003c\/strong\u003e, designed to capture the precise implant position and platform geometry for CAD\/CAM workflows. Its non-indexed design allows for flexible use in cases where the final restoration does not require a predetermined orientation or when the orientation is determined during the digital design phase after scanning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures secure and stable fixation to the implant platform or compatible interface, minimising the risk of displacement, inaccurate data capture, or the need for rescan. The scanbody is compatible with most open CAD software systems, facilitating smooth integration into digital workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed design:\u003c\/strong\u003e Flexible application for custom or free-orientation restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw fixation:\u003c\/strong\u003e Secure and reliable connection to the implant or interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor digital impressions:\u003c\/strong\u003e Accurate transmission of 3D position and platform data to CAD\/CAM systems.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Suitable for open-system intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEase of use:\u003c\/strong\u003e Easy insertion and removal without the need for auxiliary tools.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is ideal for digital workflows, especially for implant-level restorations where a predefined orientation is not required and the final alignment is determined during software-based planning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm \/ L 12 mm","offer_id":58200282628441,"sku":"526.494.030.120","price":49.32,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.5 mm \/ L 12 mm","offer_id":58200282661209,"sku":"526.494.045.120","price":49.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_1001a97a-85da-49ab-98a2-4b596435166f.jpg?v=1780484008","url":"https:\/\/shop.en.bionika.hu\/products\/di-uf-scanbody-screw-retained-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}