{"product_id":"dentum-impression-coping-for-open-tray-uniform-non-positioned","title":"BIONIKA DENTUM, Impression coping for open tray, uniform, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA Dentum\u003c\/strong\u003e implant system utilises a \u003cstrong\u003eCone \u0026amp; Hex connection geometry\u003c\/strong\u003e that ensures \u003cstrong\u003eprecise alignment\u003c\/strong\u003e and \u003cstrong\u003emicromovement-free stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWhen placed \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e, the implant enhances \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e and increases \u003cstrong\u003eprimary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e, with its \u003cstrong\u003esmaller abutment diameter\u003c\/strong\u003e, allows the bone to \u003cstrong\u003enaturally grow over the implant shoulder\u003c\/strong\u003e, protecting the \u003cstrong\u003ebone–soft tissue interface\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e efficiently \u003cstrong\u003edistributes functional loads\u003c\/strong\u003e, promoting \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e and \u003cstrong\u003esecure, micromovement-free fixation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003eself-cutting\u003c\/strong\u003e and \u003cstrong\u003ebone-condensing design\u003c\/strong\u003e provide \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e, enabling \u003cstrong\u003eimmediate loading\u003c\/strong\u003e when clinically appropriate.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eDentum\u003c\/strong\u003e system is compatible with the following implant platform:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eDentium® Superline (DM)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003eprecise fit\u003c\/strong\u003e and a \u003cstrong\u003edependable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian precision\u003c\/strong\u003e with \u003cstrong\u003eadvanced engineering innovation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUniform Design Impression Coping for Open Tray Technique with Flexible Insertion\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is an implant-level component designed for \u003cstrong\u003eopen tray impression techniques\u003c\/strong\u003e. Its \u003cstrong\u003euniform geometry\u003c\/strong\u003e ensures even distribution of the impression material, reducing the risk of distortion and providing a highly accurate and easily reproducible impression.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003enon-positioned design\u003c\/strong\u003e allows for free rotational adjustment during insertion, making the clinical workflow faster and more flexible, especially when rotational indexing is not required. The open tray technique provides precise spatial data on the implant's position, which is essential for accurate prosthetic fabrication.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUniform geometry:\u003c\/strong\u003e Consistent shape for optimal impression material flow and accuracy.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor open tray technique:\u003c\/strong\u003e Precise impression taking via direct screw access and removal.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-positioned design:\u003c\/strong\u003e Freely rotatable for quick and flexible clinical application.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level connection:\u003c\/strong\u003e Secure and reliable fit to the implant interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible material:\u003c\/strong\u003e Sterilisable, durable, and precisely machined.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is ideal for implant-level impressions in cases where rotational orientation is not required, but accurate spatial positioning is critical.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm \/ L 10 mm","offer_id":58201391825241,"sku":"615.364.030.100","price":40.14,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm \/ L 14 mm","offer_id":58201391858009,"sku":"615.364.030.140","price":40.14,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.5 mm \/ L 10 mm","offer_id":58201391890777,"sku":"615.364.045.100","price":40.14,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.5 mm \/ L 14 mm","offer_id":58201391923545,"sku":"615.364.045.140","price":40.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_nyitott_kanalhoz_03963a70-0059-4cd8-927f-364154847536.jpg?v=1780489950","url":"https:\/\/shop.en.bionika.hu\/products\/dentum-impression-coping-for-open-tray-uniform-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}