{"product_id":"dentum-impression-coping-for-closed-tray-parallel-positioned","title":"BIONIKA DENTUM, Impression coping for closed tray, parallel, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA Dentum\u003c\/strong\u003e implant system utilises a \u003cstrong\u003eCone \u0026amp; Hex connection geometry\u003c\/strong\u003e that ensures \u003cstrong\u003eprecise alignment\u003c\/strong\u003e and \u003cstrong\u003emicromovement-free stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWhen placed \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e, the implant enhances \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e and increases \u003cstrong\u003eprimary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e, with its \u003cstrong\u003esmaller abutment diameter\u003c\/strong\u003e, allows the bone to \u003cstrong\u003enaturally grow over the implant shoulder\u003c\/strong\u003e, protecting the \u003cstrong\u003ebone–soft tissue interface\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e efficiently \u003cstrong\u003edistributes functional loads\u003c\/strong\u003e, promoting \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e and \u003cstrong\u003esecure, micromovement-free fixation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003eself-cutting\u003c\/strong\u003e and \u003cstrong\u003ebone-condensing design\u003c\/strong\u003e provide \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e, enabling \u003cstrong\u003eimmediate loading\u003c\/strong\u003e when clinically appropriate.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eDentum\u003c\/strong\u003e system is compatible with the following implant platform:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eDentium® Superline (DM)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003eprecise fit\u003c\/strong\u003e and a \u003cstrong\u003edependable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian precision\u003c\/strong\u003e with \u003cstrong\u003eadvanced engineering innovation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParallel-Walled, Indexed Impression Coping for Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is an implant-level component specifically designed for accurate and stable impressions using the closed tray technique. The \u003cstrong\u003eparallel-walled geometry\u003c\/strong\u003e enhances the fit and stability of the coping within the impression material, minimizing movement and distortion during removal. This shape is particularly advantageous when high retention and minimal deviation are clinical priorities.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the coping is always repositioned in the exact same predefined orientation on the implant, enabling the precise transfer of spatial positioning to the dental laboratory. This feature is essential in multi-implant restorations where angular discrepancies between implants must be reliably reproduced.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eParallel geometry:\u003c\/strong\u003e Straight walls for enhanced stability and precise fit within the impression material.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatibility:\u003c\/strong\u003e Easier clinical procedure without removing the coping from the impression tray.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed connection:\u003c\/strong\u003e Fixed orientation for accurate and repeatable placement.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Reliable, stable connection directly to the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible, precision-machined material:\u003c\/strong\u003e Sterilizable and durable for long-term use.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is recommended in all clinical situations requiring highly accurate spatial transfer, particularly in multi-implant restorations with angulated positioning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm \/ L 12 mm","offer_id":58201391006041,"sku":"615.378.030.120","price":50.8,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.5 mm \/ L 12 mm","offer_id":58201391038809,"sku":"615.378.045.120","price":50.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_zart_kanalhoz_parallel_cd5082d8-c3f4-411c-a8a1-bf2f31b0d233.jpg?v=1780489932","url":"https:\/\/shop.en.bionika.hu\/products\/dentum-impression-coping-for-closed-tray-parallel-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}