{"product_id":"cortilog-pcl-impression-coping-for-closed-tray-parallel-positioned","title":"BIONIKA CORTILOG PCL, Impression coping for closed tray, parallel, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA Cortilog PCL\u003c\/strong\u003e implant system utilises a \u003cstrong\u003eflat-platform “tube-in-tube” connection\u003c\/strong\u003e with \u003cstrong\u003ethree cam-shaped lobes\u003c\/strong\u003e that ensure a \u003cstrong\u003erotation-proof and stable fit\u003c\/strong\u003e between the abutment and the implant.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThis \u003cstrong\u003eprecise engagement\u003c\/strong\u003e provides \u003cstrong\u003emicromovement-free force transmission\u003c\/strong\u003e and \u003cstrong\u003elong-term biomechanical stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003ePlacement \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e supports \u003cstrong\u003ebone preservation\u003c\/strong\u003e and enhances \u003cstrong\u003eprimary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e efficiently \u003cstrong\u003edistributes functional loads\u003c\/strong\u003e, promoting \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e while \u003cstrong\u003eminimising micromovements\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003eself-cutting\u003c\/strong\u003e and \u003cstrong\u003ebone-condensing thread geometry\u003c\/strong\u003e allow for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e when appropriate, while the \u003cstrong\u003erounded implant apex\u003c\/strong\u003e facilitates \u003cstrong\u003eeasy and accurate surgical placement\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eCortilog PCL\u003c\/strong\u003e system is compatible with the following platform:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eCAMLOG®\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003eprecisely fitting\u003c\/strong\u003e and \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian precision\u003c\/strong\u003e with \u003cstrong\u003eadvanced engineering expertise\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParallel-Walled, Indexed Impression Coping for Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is an implant-level component specifically designed for accurate and stable impressions using the closed tray technique. The \u003cstrong\u003eparallel-walled geometry\u003c\/strong\u003e enhances the fit and stability of the coping within the impression material, minimizing movement and distortion during removal. This shape is particularly advantageous when high retention and minimal deviation are clinical priorities.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the coping is always repositioned in the exact same predefined orientation on the implant, enabling the precise transfer of spatial positioning to the dental laboratory. This feature is essential in multi-implant restorations where angular discrepancies between implants must be reliably reproduced.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eParallel geometry:\u003c\/strong\u003e Straight walls for enhanced stability and precise fit within the impression material.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatibility:\u003c\/strong\u003e Easier clinical procedure without removing the coping from the impression tray.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed connection:\u003c\/strong\u003e Fixed orientation for accurate and repeatable placement.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Reliable, stable connection directly to the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible, precision-machined material:\u003c\/strong\u003e Sterilizable and durable for long-term use.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is recommended in all clinical situations requiring highly accurate spatial transfer, particularly in multi-implant restorations with angulated positioning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.3 mm (gray) \/ L 12 mm","offer_id":58201197838681,"sku":"519.378.033.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.8 mm (yellow) \/ L 12 mm","offer_id":58201197871449,"sku":"519.378.038.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.3 mm (purple) \/ L 12 mm","offer_id":58201197904217,"sku":"519.378.043.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 5 mm (blue) \/ L 12 mm","offer_id":58201197936985,"sku":"519.378.050.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 6 mm (green) \/ L 12 mm","offer_id":58201197969753,"sku":"519.378.060.120","price":58.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/BIONIKA_Cortilog_PCL_Mintaveteli_fej_zart_kanalhoz_parallel_mod_032a2a4c-ca2f-4b4a-b81f-0d32ca2e48c2.jpg?v=1780489378","url":"https:\/\/shop.en.bionika.hu\/products\/cortilog-pcl-impression-coping-for-closed-tray-parallel-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}