{"product_id":"cortilog-pcl-implant-driver-manual-lamellar-bionika","title":"BIONIKA CORTILOG PCL, Implant driver, manual, lamellar, Bionika","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA Cortilog PCL\u003c\/strong\u003e implant system utilises a \u003cstrong\u003eflat-platform “tube-in-tube” connection\u003c\/strong\u003e with \u003cstrong\u003ethree cam-shaped lobes\u003c\/strong\u003e that ensure a \u003cstrong\u003erotation-proof and stable fit\u003c\/strong\u003e between the abutment and the implant.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThis \u003cstrong\u003eprecise engagement\u003c\/strong\u003e provides \u003cstrong\u003emicromovement-free force transmission\u003c\/strong\u003e and \u003cstrong\u003elong-term biomechanical stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003ePlacement \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e supports \u003cstrong\u003ebone preservation\u003c\/strong\u003e and enhances \u003cstrong\u003eprimary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e efficiently \u003cstrong\u003edistributes functional loads\u003c\/strong\u003e, promoting \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e while \u003cstrong\u003eminimising micromovements\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003eself-cutting\u003c\/strong\u003e and \u003cstrong\u003ebone-condensing thread geometry\u003c\/strong\u003e allow for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e when appropriate, while the \u003cstrong\u003erounded implant apex\u003c\/strong\u003e facilitates \u003cstrong\u003eeasy and accurate surgical placement\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eCortilog PCL\u003c\/strong\u003e system is compatible with the following platform:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eCAMLOG®\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003eprecisely fitting\u003c\/strong\u003e and \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian precision\u003c\/strong\u003e with \u003cstrong\u003eadvanced engineering expertise\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eManual Implant Driver with Lamellar Design for Bionika System\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImplant driver, manual, lamellar, Bionika\u003c\/strong\u003e is a \u003cstrong\u003esurgical tool designed for manual use\u003c\/strong\u003e, developed specifically for the precise insertion of Bionika system implants with lamellar connection. The \u003cstrong\u003elamellar connection tip\u003c\/strong\u003e ensures perfect fit with the internal geometry of the implant, allowing for \u003cstrong\u003estable and vibration-free torque transfer\u003c\/strong\u003e during placement.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nManual use of this driver is particularly advantageous in cases requiring \u003cstrong\u003ehigh control and precision\u003c\/strong\u003e—such as in the anterior region, in low bone density, or in anatomically challenging areas. Made of \u003cstrong\u003emedical-grade stainless steel\u003c\/strong\u003e, the device is \u003cstrong\u003esterilisable, durable, and reusable\u003c\/strong\u003e.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eLamellar design:\u003c\/strong\u003e Perfect fit for lamellar implants in the Bionika system.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eManual control:\u003c\/strong\u003e Fine guidance and precision during every step of insertion.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eVibration-free torque transfer:\u003c\/strong\u003e Safe and accurate positioning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eMedical-grade stainless steel:\u003c\/strong\u003e Long-lasting and reliable clinical performance.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eSterilisable and reusable:\u003c\/strong\u003e Cost-effective and environmentally conscious solution.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication Area:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImplant driver, manual, lamellar, Bionika\u003c\/strong\u003e is an ideal choice for the manual placement of lamellar implants from the Bionika system, particularly when precision control and anatomical safety are top priorities.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only. Colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.3 mm (gray) \/ L 6 mm","offer_id":58201322553689,"sku":"519.198.033.060","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.3 mm (gray) \/ L 12 mm","offer_id":58201322586457,"sku":"519.198.033.120","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.3 mm (gray) \/ L 18 mm","offer_id":58201322619225,"sku":"519.198.033.180","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.8 mm (yellow) \/ L 6 mm","offer_id":58201322651993,"sku":"519.198.038.060","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.8 mm (yellow) \/ L 12 mm","offer_id":58201322684761,"sku":"519.198.038.120","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.8 mm (yellow) \/ L 18 mm","offer_id":58201322717529,"sku":"519.198.038.180","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.3 mm (purple) \/ L 6 mm","offer_id":58201322750297,"sku":"519.198.043.060","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.3 mm (purple) \/ L 12 mm","offer_id":58201322783065,"sku":"519.198.043.120","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.3 mm (purple) \/ L 18 mm","offer_id":58201322815833,"sku":"519.198.043.180","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 5 mm (blue) \/ L 6 mm","offer_id":58201322848601,"sku":"519.198.050.060","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 5 mm (blue) \/ L 12 mm","offer_id":58201322881369,"sku":"519.198.050.120","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 5 mm (blue) \/ L 18 mm","offer_id":58201322914137,"sku":"519.198.050.180","price":44.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/uniform_implantatum_behajto_kezi_lamellas_bionika_f0ac4962-9c39-4a16-b674-fdd64188cd5b.jpg?v=1780489589","url":"https:\/\/shop.en.bionika.hu\/products\/cortilog-pcl-implant-driver-manual-lamellar-bionika","provider":"BIONIKA Webshop","version":"1.0","type":"link"}