{"product_id":"cortilog-pcl-abutment-screw-for-angled-multi-unit-abutment","title":"BIONIKA CORTILOG PCL, Abutment screw for angled multi-unit abutment","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA Cortilog PCL\u003c\/strong\u003e implant system utilises a \u003cstrong\u003eflat-platform “tube-in-tube” connection\u003c\/strong\u003e with \u003cstrong\u003ethree cam-shaped lobes\u003c\/strong\u003e that ensure a \u003cstrong\u003erotation-proof and stable fit\u003c\/strong\u003e between the abutment and the implant.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThis \u003cstrong\u003eprecise engagement\u003c\/strong\u003e provides \u003cstrong\u003emicromovement-free force transmission\u003c\/strong\u003e and \u003cstrong\u003elong-term biomechanical stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003ePlacement \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e supports \u003cstrong\u003ebone preservation\u003c\/strong\u003e and enhances \u003cstrong\u003eprimary stability\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e efficiently \u003cstrong\u003edistributes functional loads\u003c\/strong\u003e, promoting \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e while \u003cstrong\u003eminimising micromovements\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003eself-cutting\u003c\/strong\u003e and \u003cstrong\u003ebone-condensing thread geometry\u003c\/strong\u003e allow for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e when appropriate, while the \u003cstrong\u003erounded implant apex\u003c\/strong\u003e facilitates \u003cstrong\u003eeasy and accurate surgical placement\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eCortilog PCL\u003c\/strong\u003e system is compatible with the following platform:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eCAMLOG®\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003eprecisely fitting\u003c\/strong\u003e and \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian precision\u003c\/strong\u003e with \u003cstrong\u003eadvanced engineering expertise\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecialised Screw for Angled Multi-Unit Prosthetic Abutments\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003eThe \u003cstrong\u003eAbutment screw for angled multi-unit abutment\u003c\/strong\u003e is a \u003cstrong\u003eprecision-engineered titanium fixation screw\u003c\/strong\u003e specifically designed for the stable retention of angled multi-unit abutments and their associated restorations. Its geometry and length dimensions are tailored to match the inclination of the angled abutment and the internal thread position, ensuring optimal force distribution and proper seating of the screw head—even when the insertion axis differs from the prosthetic axis.\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003eThis screw provides reliable fixation for full-arch or multi-unit screw-retained restorations, and its design allows for repeated reinsertion without damaging the implant or the multi-unit abutment. The \u003cstrong\u003ebiocompatible titanium material\u003c\/strong\u003e ensures high strength, corrosion resistance, and long-term clinical reliability.\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDesigned for angled multi-unit abutments:\u003c\/strong\u003e Perfect fit with angle-compensated screw head geometry.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eStable retention:\u003c\/strong\u003e Ensures secure connection to prosthetic components and restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eTitanium material:\u003c\/strong\u003e Biocompatible, durable, sterilisable, and corrosion-resistant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eReusable design:\u003c\/strong\u003e Suitable for restorations requiring repeated insertion and removal.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eAccurate force transmission:\u003c\/strong\u003e Minimises the risk of screw loosening in multi-unit prosthetics.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003eThe \u003cstrong\u003eAbutment screw for angled multi-unit abutment\u003c\/strong\u003e is the ideal choice for prosthetic work requiring secure screw-retained fixation on angled multi-unit abutments—especially in full-arch, hybrid, or All-on restorations.\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only. The colour and geometry of the product may vary depending on the selected size.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"M 1.6 mm","offer_id":58201322979673,"sku":"519.078.016.000","price":14.5,"currency_code":"EUR","in_stock":true},{"title":"M 2 mm","offer_id":58201323012441,"sku":"519.078.020.000","price":14.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Fejcsavar_ferde_Multi_unit_fejhez_1_92a353f4-c1a1-47d8-92d3-0db61c4304f0.jpg?v=1780489591","url":"https:\/\/shop.en.bionika.hu\/products\/cortilog-pcl-abutment-screw-for-angled-multi-unit-abutment","provider":"BIONIKA Webshop","version":"1.0","type":"link"}