{"product_id":"corticon-implant-driver-manual-lamellar-bionika","title":"BIONIKA CORTICON, Implant driver, manual, lamellar, Bionika","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA Corticon\u003c\/strong\u003e implant system utilises a \u003cstrong\u003econical and hexagonal (Cone \u0026amp; Hex) connection geometry\u003c\/strong\u003e that ensures \u003cstrong\u003eexceptionally precise\u003c\/strong\u003e, \u003cstrong\u003emicromovement-free engagement\u003c\/strong\u003e and \u003cstrong\u003ereliable force transmission\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eImplant placement \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e is recommended, as this position \u003cstrong\u003eenhances primary stability\u003c\/strong\u003e and supports \u003cstrong\u003elong-term bone level maintenance\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eplatform-switching design\u003c\/strong\u003e allows the bone to \u003cstrong\u003enaturally grow over the implant shoulder\u003c\/strong\u003e, resulting in a \u003cstrong\u003estable biological seal\u003c\/strong\u003e and \u003cstrong\u003efavourable soft tissue response\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally ribbed, self-locking thread structure\u003c\/strong\u003e provides \u003cstrong\u003eoptimal load-bearing capacity\u003c\/strong\u003e, \u003cstrong\u003epromotes rapid osseointegration\u003c\/strong\u003e, and \u003cstrong\u003eminimises micromovements\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eOwing to its \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e, \u003cstrong\u003ehigh thread pitch\u003c\/strong\u003e, and \u003cstrong\u003ebone-condensing thread profile\u003c\/strong\u003e, the implant offers \u003cstrong\u003eexcellent primary stability\u003c\/strong\u003e, even under \u003cstrong\u003eimmediate loading\u003c\/strong\u003e conditions.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eCorticon\u003c\/strong\u003e system is compatible with the following implant platform:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eOsstem® (OS)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt provides a \u003cstrong\u003eprecise fit\u003c\/strong\u003e and a \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to leading international implant systems, combining \u003cstrong\u003eHungarian precision\u003c\/strong\u003e with \u003cstrong\u003eadvanced engineering innovation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eManual Implant Driver with Lamellar Design for Bionika System\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImplant driver, manual, lamellar, Bionika\u003c\/strong\u003e is a \u003cstrong\u003esurgical tool designed for manual use\u003c\/strong\u003e, developed specifically for the precise insertion of Bionika system implants with lamellar connection. The \u003cstrong\u003elamellar connection tip\u003c\/strong\u003e ensures perfect fit with the internal geometry of the implant, allowing for \u003cstrong\u003estable and vibration-free torque transfer\u003c\/strong\u003e during placement.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nManual use of this driver is particularly advantageous in cases requiring \u003cstrong\u003ehigh control and precision\u003c\/strong\u003e—such as in the anterior region, in low bone density, or in anatomically challenging areas. Made of \u003cstrong\u003emedical-grade stainless steel\u003c\/strong\u003e, the device is \u003cstrong\u003esterilisable, durable, and reusable\u003c\/strong\u003e.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eLamellar design:\u003c\/strong\u003e Perfect fit for lamellar implants in the Bionika system.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eManual control:\u003c\/strong\u003e Fine guidance and precision during every step of insertion.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eVibration-free torque transfer:\u003c\/strong\u003e Safe and accurate positioning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eMedical-grade stainless steel:\u003c\/strong\u003e Long-lasting and reliable clinical performance.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eSterilisable and reusable:\u003c\/strong\u003e Cost-effective and environmentally conscious solution.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication Area:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImplant driver, manual, lamellar, Bionika\u003c\/strong\u003e is an ideal choice for the manual placement of lamellar implants from the Bionika system, particularly when precision control and anatomical safety are top priorities.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only. Colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3 mm (gray) \/ L 6 mm","offer_id":58201183748441,"sku":"550.198.030.060","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm (gray) \/ L 12 mm","offer_id":58201183781209,"sku":"550.198.030.120","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3 mm (gray) \/ L 18 mm","offer_id":58201183813977,"sku":"550.198.030.180","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm (yellow) \/ L 6 mm","offer_id":58201183846745,"sku":"550.198.035.060","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm (yellow) \/ L 12 mm","offer_id":58201183879513,"sku":"550.198.035.120","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm (yellow) \/ L 18 mm","offer_id":58201183912281,"sku":"550.198.035.180","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (purple) \/ L 6 mm","offer_id":58201183945049,"sku":"550.198.040.060","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (purple) \/ L 12 mm","offer_id":58201183977817,"sku":"550.198.040.120","price":44.4,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (purple) \/ L 18 mm","offer_id":58201184010585,"sku":"550.198.040.180","price":44.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/uniform_implantatum_behajto_kezi_lamellas_bionika_07848185-9e35-45a5-8c1a-2e08f5124d9d.jpg?v=1780489278","url":"https:\/\/shop.en.bionika.hu\/products\/corticon-implant-driver-manual-lamellar-bionika","provider":"BIONIKA Webshop","version":"1.0","type":"link"}