{"product_id":"c1-scanbody-screw-retained-non-positioned","title":"BIONIKA C1, Scanbody, screw-retained, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA C1\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eMIS® C1®\u003c\/strong\u003e platform and features an \u003cstrong\u003einternal conical connection (Conical-Connection)\u003c\/strong\u003e that ensures \u003cstrong\u003emicromovement-free fitting\u003c\/strong\u003e and \u003cstrong\u003eoptimal load distribution\u003c\/strong\u003e. The \u003cstrong\u003e12° Morse taper\u003c\/strong\u003e provides a stable, \u003cstrong\u003ebacteria-tight seal\u003c\/strong\u003e between the abutment and the implant, promoting \u003cstrong\u003elong-term bone and soft tissue preservation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-compressing thread design\u003c\/strong\u003e offers \u003cstrong\u003ehigh primary stability\u003c\/strong\u003e, while the \u003cem\u003eplatform switching\u003c\/em\u003e configuration supports \u003cstrong\u003ebiological width maintenance\u003c\/strong\u003e and \u003cstrong\u003ebone-level protection\u003c\/strong\u003e. Its \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e and \u003cstrong\u003eself-cutting, self-locking threads\u003c\/strong\u003e allow for \u003cstrong\u003equick and precise insertion\u003c\/strong\u003e with \u003cstrong\u003eminimal surgical trauma\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA C1\u003c\/strong\u003e system is an ideal solution for \u003cstrong\u003eaesthetic and functional implant restorations\u003c\/strong\u003e where \u003cstrong\u003ebone preservation, stability,\u003c\/strong\u003e and \u003cstrong\u003elong-term reliability\u003c\/strong\u003e are essential.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNon-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is a \u003cstrong\u003edevice used for intraoral or laboratory digital impressions\u003c\/strong\u003e, designed to capture the precise implant position and platform geometry for CAD\/CAM workflows. Its non-indexed design allows for flexible use in cases where the final restoration does not require a predetermined orientation or when the orientation is determined during the digital design phase after scanning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures secure and stable fixation to the implant platform or compatible interface, minimising the risk of displacement, inaccurate data capture, or the need for rescan. The scanbody is compatible with most open CAD software systems, facilitating smooth integration into digital workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed design:\u003c\/strong\u003e Flexible application for custom or free-orientation restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw fixation:\u003c\/strong\u003e Secure and reliable connection to the implant or interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor digital impressions:\u003c\/strong\u003e Accurate transmission of 3D position and platform data to CAD\/CAM systems.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Suitable for open-system intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEase of use:\u003c\/strong\u003e Easy insertion and removal without the need for auxiliary tools.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is ideal for digital workflows, especially for implant-level restorations where a predefined orientation is not required and the final alignment is determined during software-based planning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 2.75 mm (yellow) \/ L 12 mm","offer_id":58199402971481,"sku":"548.494.275.120","price":54.8,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.15 mm (purple) \/ L 12 mm","offer_id":58199403004249,"sku":"548.494.315.120","price":54.8,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (green) \/ L 12 mm","offer_id":58199403037017,"sku":"548.494.040.120","price":54.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_2d5de9bd-c186-412b-8e48-455c5e5b4ad1.jpg?v=1780479790","url":"https:\/\/shop.en.bionika.hu\/products\/c1-scanbody-screw-retained-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}