{"product_id":"c1-impression-coping-for-closed-tray-parallel-positioned","title":"BIONIKA C1, Impression coping for closed tray, parallel, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA C1\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eMIS® C1®\u003c\/strong\u003e platform and features an \u003cstrong\u003einternal conical connection (Conical-Connection)\u003c\/strong\u003e that ensures \u003cstrong\u003emicromovement-free fitting\u003c\/strong\u003e and \u003cstrong\u003eoptimal load distribution\u003c\/strong\u003e. The \u003cstrong\u003e12° Morse taper\u003c\/strong\u003e provides a stable, \u003cstrong\u003ebacteria-tight seal\u003c\/strong\u003e between the abutment and the implant, promoting \u003cstrong\u003elong-term bone and soft tissue preservation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-compressing thread design\u003c\/strong\u003e offers \u003cstrong\u003ehigh primary stability\u003c\/strong\u003e, while the \u003cem\u003eplatform switching\u003c\/em\u003e configuration supports \u003cstrong\u003ebiological width maintenance\u003c\/strong\u003e and \u003cstrong\u003ebone-level protection\u003c\/strong\u003e. Its \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e and \u003cstrong\u003eself-cutting, self-locking threads\u003c\/strong\u003e allow for \u003cstrong\u003equick and precise insertion\u003c\/strong\u003e with \u003cstrong\u003eminimal surgical trauma\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA C1\u003c\/strong\u003e system is an ideal solution for \u003cstrong\u003eaesthetic and functional implant restorations\u003c\/strong\u003e where \u003cstrong\u003ebone preservation, stability,\u003c\/strong\u003e and \u003cstrong\u003elong-term reliability\u003c\/strong\u003e are essential.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParallel-Walled, Indexed Impression Coping for Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is an implant-level component specifically designed for accurate and stable impressions using the closed tray technique. The \u003cstrong\u003eparallel-walled geometry\u003c\/strong\u003e enhances the fit and stability of the coping within the impression material, minimizing movement and distortion during removal. This shape is particularly advantageous when high retention and minimal deviation are clinical priorities.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the coping is always repositioned in the exact same predefined orientation on the implant, enabling the precise transfer of spatial positioning to the dental laboratory. This feature is essential in multi-implant restorations where angular discrepancies between implants must be reliably reproduced.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eParallel geometry:\u003c\/strong\u003e Straight walls for enhanced stability and precise fit within the impression material.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatibility:\u003c\/strong\u003e Easier clinical procedure without removing the coping from the impression tray.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed connection:\u003c\/strong\u003e Fixed orientation for accurate and repeatable placement.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Reliable, stable connection directly to the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible, precision-machined material:\u003c\/strong\u003e Sterilizable and durable for long-term use.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is recommended in all clinical situations requiring highly accurate spatial transfer, particularly in multi-implant restorations with angulated positioning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 2.75 mm (yellow) \/ L 12 mm","offer_id":58199355654489,"sku":"548.378.275.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.15 mm (purple) \/ L 12 mm","offer_id":58199355687257,"sku":"548.378.315.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (green) \/ L 12 mm","offer_id":58199355720025,"sku":"548.378.040.120","price":58.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_zart_kanalhoz_parallel_099ba4ed-7ad6-436e-9543-2e522b3950ae.jpg?v=1780479606","url":"https:\/\/shop.en.bionika.hu\/products\/c1-impression-coping-for-closed-tray-parallel-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}