{"product_id":"br-scanbody-screw-retained-non-positioned","title":"BIONIKA BR, Scanbody, screw-retained, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA BR\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eNobel® Branemark®\u003c\/strong\u003e platform and features a \u003cstrong\u003eclassic internal hex connection (Internal Hex Connection)\u003c\/strong\u003e, offering the proven \u003cstrong\u003estability\u003c\/strong\u003e and \u003cstrong\u003ereliability\u003c\/strong\u003e established over decades of clinical success.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe implant design combines a \u003cstrong\u003etraditional parallel-walled body geometry\u003c\/strong\u003e with modern manufacturing precision, ensuring excellent \u003cstrong\u003eprimary stability\u003c\/strong\u003e across various bone qualities. The \u003cstrong\u003emicro-grooved collar\u003c\/strong\u003e enhances bone integration and reduces bone resorption, while the \u003cstrong\u003edeep thread profile\u003c\/strong\u003e optimises load distribution.\u003c\/p\u003e\u003cp align=\"\" justify\u003eIts \u003cstrong\u003eself-cutting thread\u003c\/strong\u003e and \u003cstrong\u003eanatomical root-shaped body\u003c\/strong\u003e allow for easy insertion and rapid \u003cstrong\u003eosseointegration\u003c\/strong\u003e. The \u003cstrong\u003eBIONIKA BR\u003c\/strong\u003e system is an ideal choice for clinicians using the traditional \u003cstrong\u003eBranemark concept\u003c\/strong\u003e who seek a modern, reliable implant solution built on a trusted foundation.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNon-indexed scanbody for digital impressions with pass-through screw retention\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is a \u003cstrong\u003edevice used for intraoral or laboratory digital impressions\u003c\/strong\u003e, designed to capture the precise implant position and platform geometry for CAD\/CAM workflows. Its non-indexed design allows for flexible use in cases where the final restoration does not require a predetermined orientation or when the orientation is determined during the digital design phase after scanning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003epass-through screw retention\u003c\/strong\u003e ensures secure and stable fixation to the implant platform or compatible interface, minimising the risk of displacement, inaccurate data capture, or the need for rescan. The scanbody is compatible with most open CAD software systems, facilitating smooth integration into digital workflows.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain benefits:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed design:\u003c\/strong\u003e Flexible application for custom or free-orientation restorations.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePass-through screw fixation:\u003c\/strong\u003e Secure and reliable connection to the implant or interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor digital impressions:\u003c\/strong\u003e Accurate transmission of 3D position and platform data to CAD\/CAM systems.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Suitable for open-system intraoral and lab scanners.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eEase of use:\u003c\/strong\u003e Easy insertion and removal without the need for auxiliary tools.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eScanbody, screw-retained, non-positioned\u003c\/strong\u003e is ideal for digital workflows, especially for implant-level restorations where a predefined orientation is not required and the final alignment is determined during software-based planning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; actual colour and geometry may vary depending on the selected dimensions.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm \/ L 12 mm","offer_id":58197263712601,"sku":"516.494.035.120","price":65.76,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.1 mm \/ L 12 mm","offer_id":58197263745369,"sku":"516.494.041.120","price":65.76,"currency_code":"EUR","in_stock":true},{"title":"Ø 5.1 mm \/ L 12 mm","offer_id":58197263778137,"sku":"516.494.051.120","price":65.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Scanbody_fej_atmenocsavaros_pozicionalt_c3c8e47f-6f40-4eec-ba68-c0570bfdecea.jpg?v=1780466899","url":"https:\/\/shop.en.bionika.hu\/products\/br-scanbody-screw-retained-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}