{"product_id":"bonelit-impression-coping-for-closed-tray-parallel-positioned","title":"BIONIKA BONELIT, Impression coping for closed tray, parallel, positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA Bonelit\u003c\/strong\u003e implant system utilizes an \u003cstrong\u003eadvanced “tube-in-tube” connection concept\u003c\/strong\u003e with a \u003cstrong\u003efour-position, ribbed anti-rotation design\u003c\/strong\u003e that ensures a \u003cstrong\u003estable, micromovement-free fit\u003c\/strong\u003e between the abutment and the implant.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003econical precision connection\u003c\/strong\u003e provides \u003cstrong\u003eoptimal force transmission\u003c\/strong\u003e by directing loads \u003cstrong\u003edeep into the implant body\u003c\/strong\u003e, thereby \u003cstrong\u003ereducing stress on the cortical bone\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003ePlacement \u003cstrong\u003eat or slightly below the cortical level\u003c\/strong\u003e is recommended to \u003cstrong\u003eenhance primary stability\u003c\/strong\u003e and maintain \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003einternal platform-switching design\u003c\/strong\u003e allows the bone to \u003cstrong\u003enaturally grow over the implant shoulder\u003c\/strong\u003e, providing \u003cstrong\u003ebiological sealing\u003c\/strong\u003e and \u003cstrong\u003elasting bone preservation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking thread structure\u003c\/strong\u003e combined with the \u003cstrong\u003ebone-condensing, anatomical root-shaped body\u003c\/strong\u003e ensures \u003cstrong\u003erapid osseointegration\u003c\/strong\u003e, \u003cstrong\u003ehigh primary stability\u003c\/strong\u003e, and suitability for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003erounded implant apex\u003c\/strong\u003e facilitates \u003cstrong\u003esurgical placement\u003c\/strong\u003e, ensuring \u003cstrong\u003eaccurate positioning\u003c\/strong\u003e and \u003cstrong\u003eminimal bone stress\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA Bonelit\u003c\/strong\u003e system is compatible with the following platforms:\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eICX® da Vinci®\u003c\/li\u003e  \u003cli\u003eStraumann® BoneLevel®\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp align=\"\" justify\u003eIt offers a \u003cstrong\u003ereliable alternative\u003c\/strong\u003e to \u003cstrong\u003epremium implant systems\u003c\/strong\u003e, combining \u003cstrong\u003eHungarian precision\u003c\/strong\u003e with \u003cstrong\u003einnovative engineering excellence\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParallel-Walled, Indexed Impression Coping for Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is an implant-level component specifically designed for accurate and stable impressions using the closed tray technique. The \u003cstrong\u003eparallel-walled geometry\u003c\/strong\u003e enhances the fit and stability of the coping within the impression material, minimizing movement and distortion during removal. This shape is particularly advantageous when high retention and minimal deviation are clinical priorities.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eindexed design\u003c\/strong\u003e ensures that the coping is always repositioned in the exact same predefined orientation on the implant, enabling the precise transfer of spatial positioning to the dental laboratory. This feature is essential in multi-implant restorations where angular discrepancies between implants must be reliably reproduced.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eParallel geometry:\u003c\/strong\u003e Straight walls for enhanced stability and precise fit within the impression material.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatibility:\u003c\/strong\u003e Easier clinical procedure without removing the coping from the impression tray.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eIndexed connection:\u003c\/strong\u003e Fixed orientation for accurate and repeatable placement.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level fit:\u003c\/strong\u003e Reliable, stable connection directly to the implant.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible, precision-machined material:\u003c\/strong\u003e Sterilizable and durable for long-term use.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, parallel, positioned\u003c\/strong\u003e is recommended in all clinical situations requiring highly accurate spatial transfer, particularly in multi-implant restorations with angulated positioning.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected specifications.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 2.9 mm (blue) \/ L 12 mm","offer_id":58200846598489,"sku":"555.378.029.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.3 mm (yellow) \/ L 12 mm","offer_id":58200846631257,"sku":"555.378.033.120","price":58.0,"currency_code":"EUR","in_stock":true},{"title":"Ø 4.1 mm (purple) \/ L 12 mm","offer_id":58200846664025,"sku":"555.378.041.120","price":58.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_zart_kanalhoz_parallel_29d4106f-cc24-4138-a553-18d83fc431dc.jpg?v=1780488312","url":"https:\/\/shop.en.bionika.hu\/products\/bonelit-impression-coping-for-closed-tray-parallel-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}