{"product_id":"bb-impression-coping-for-open-tray-uniform-non-positioned","title":"BIONIKA BB, Impression coping for open tray, uniform, non-positioned","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA BB\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eBredent® SKY platform\u003c\/strong\u003e and features a \u003cstrong\u003econical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e with a precise, \u003cstrong\u003emicromovement-free fit\u003c\/strong\u003e that ensures stable load transfer.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e30° conical interface\u003c\/strong\u003e directs forces deep into the implant body, thereby reducing \u003cstrong\u003ecortical stress\u003c\/strong\u003e and promoting \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking, and self-compressing thread profile\u003c\/strong\u003e provides strong \u003cstrong\u003eprimary stability\u003c\/strong\u003e, particularly suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e design supports the \u003cstrong\u003ebiological sealing of soft tissues\u003c\/strong\u003e and helps maintain an \u003cstrong\u003eaesthetic gingival contour\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e, \u003cstrong\u003erounded apex\u003c\/strong\u003e, and \u003cstrong\u003ebone-condensing thread geometry\u003c\/strong\u003e, the \u003cstrong\u003eBB implant\u003c\/strong\u003e offers an excellent solution for \u003cstrong\u003estable, long-lasting restorations\u003c\/strong\u003e that meet both \u003cstrong\u003eaesthetic and functional demands\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUniform Design Impression Coping for Open Tray Technique with Flexible Insertion\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is an implant-level component designed for \u003cstrong\u003eopen tray impression techniques\u003c\/strong\u003e. Its \u003cstrong\u003euniform geometry\u003c\/strong\u003e ensures even distribution of the impression material, reducing the risk of distortion and providing a highly accurate and easily reproducible impression.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003enon-positioned design\u003c\/strong\u003e allows for free rotational adjustment during insertion, making the clinical workflow faster and more flexible, especially when rotational indexing is not required. The open tray technique provides precise spatial data on the implant's position, which is essential for accurate prosthetic fabrication.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUniform geometry:\u003c\/strong\u003e Consistent shape for optimal impression material flow and accuracy.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFor open tray technique:\u003c\/strong\u003e Precise impression taking via direct screw access and removal.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-positioned design:\u003c\/strong\u003e Freely rotatable for quick and flexible clinical application.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImplant-level connection:\u003c\/strong\u003e Secure and reliable fit to the implant interface.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible material:\u003c\/strong\u003e Sterilisable, durable, and precisely machined.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for open tray, uniform, non-positioned\u003c\/strong\u003e is ideal for implant-level impressions in cases where rotational orientation is not required, but accurate spatial positioning is critical.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"Ø 3.5 mm (yellow) \/ L 10 mm","offer_id":58199642767705,"sku":"545.364.035.100","price":49.06,"currency_code":"EUR","in_stock":true},{"title":"Ø 3.5 mm (yellow) \/ L 14 mm","offer_id":58199642800473,"sku":"545.364.035.140","price":49.06,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (purple) \/ L 10 mm","offer_id":58199642833241,"sku":"545.364.040.100","price":49.06,"currency_code":"EUR","in_stock":true},{"title":"Ø 4 mm (purple) \/ L 14 mm","offer_id":58199642866009,"sku":"545.364.040.140","price":49.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/Compatible_Mintaveteli_fej_nyitott_kanalhoz_b80d8a86-c71e-4698-a875-66ef81d18cb5.jpg?v=1780481599","url":"https:\/\/shop.en.bionika.hu\/products\/bb-impression-coping-for-open-tray-uniform-non-positioned","provider":"BIONIKA Webshop","version":"1.0","type":"link"}