{"product_id":"bb-impression-coping-for-closed-tray-multi-unit-level-non-positioned-narrow","title":"BIONIKA BB, Impression coping for closed tray, multi-unit level, non-positioned, narrow","description":"\u003cp\u003eBrand characteristics\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003eBIONIKA BB\u003c\/strong\u003e implant system is compatible with the \u003cstrong\u003eBredent® SKY platform\u003c\/strong\u003e and features a \u003cstrong\u003econical and hexagonal (Cone \u0026amp; Hex) connection\u003c\/strong\u003e with a precise, \u003cstrong\u003emicromovement-free fit\u003c\/strong\u003e that ensures stable load transfer.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003e30° conical interface\u003c\/strong\u003e directs forces deep into the implant body, thereby reducing \u003cstrong\u003ecortical stress\u003c\/strong\u003e and promoting \u003cstrong\u003elong-term bone preservation\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cstrong\u003espirally micro-grooved, self-locking, and self-compressing thread profile\u003c\/strong\u003e provides strong \u003cstrong\u003eprimary stability\u003c\/strong\u003e, particularly suitable for \u003cstrong\u003eimmediate loading\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eThe \u003cem\u003eplatform switching\u003c\/em\u003e design supports the \u003cstrong\u003ebiological sealing of soft tissues\u003c\/strong\u003e and helps maintain an \u003cstrong\u003eaesthetic gingival contour\u003c\/strong\u003e.\u003c\/p\u003e\u003cp align=\"\" justify\u003eWith its \u003cstrong\u003eanatomical root-shaped design\u003c\/strong\u003e, \u003cstrong\u003erounded apex\u003c\/strong\u003e, and \u003cstrong\u003ebone-condensing thread geometry\u003c\/strong\u003e, the \u003cstrong\u003eBB implant\u003c\/strong\u003e offers an excellent solution for \u003cstrong\u003estable, long-lasting restorations\u003c\/strong\u003e that meet both \u003cstrong\u003eaesthetic and functional demands\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eGeometry characteristics\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNarrow Impression Coping for Multi-Unit Systems – Closed Tray Technique\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, multi-unit level, non-positioned, narrow\u003c\/strong\u003e is a dedicated component designed for accurate impressions in \u003cstrong\u003emulti-unit systems\u003c\/strong\u003e that connect multiple implants. Its \u003cstrong\u003enarrow design\u003c\/strong\u003e offers clear advantages in tight anatomical spaces or small interproximal gaps, facilitating easier insertion and improved fit within the impression tray.\r\n\u003c\/p\u003e\r\n\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003enon-indexed configuration\u003c\/strong\u003e allows for free rotation of the coping, simplifying clinical placement in cases where orientation is not critical. The \u003cstrong\u003eclosed tray technique\u003c\/strong\u003e enables quick and efficient impression taking without removing the coping from the patient’s mouth during the procedure.\r\n\u003c\/p\u003e\r\n\r\n\u003ch4\u003eMain Advantages:\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNarrow form:\u003c\/strong\u003e Ideal for limited implant spacing and narrow multi-unit abutments.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eMulti-unit level connection:\u003c\/strong\u003e Accurate fit with multi-unit prosthetic structures.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eClosed tray compatible:\u003c\/strong\u003e Simplifies and shortens the impression procedure.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-indexed design:\u003c\/strong\u003e Flexible insertion with free rotational positioning.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBiocompatible material:\u003c\/strong\u003e Precisely machined, durable, and sterilisable.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eIndications:\u003c\/h4\u003e\r\n\u003cp align=\"justify\"\u003e\r\nThe \u003cstrong\u003eImpression coping for closed tray, multi-unit level, non-positioned, narrow\u003c\/strong\u003e is recommended for clinical cases involving multiple implants in confined anatomical areas, where fixed orientation is not required.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cem\u003eThe product image is for illustration purposes only; colour and geometry may vary depending on the selected parameters.\u003c\/em\u003e\u003c\/p\u003e","brand":"BIONIKA Medline Kft.","offers":[{"title":"L 10 mm","offer_id":58199641358681,"sku":"545.798.100.000","price":36.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/6850\/2495\/files\/uniform_mintaveteli_fej_zart_kanalhoz_multi_unit_szintu_nem_pozicionalt_8ab2c891-bac1-43b7-a4e7-042258f5fa45.jpg?v=1780481577","url":"https:\/\/shop.en.bionika.hu\/products\/bb-impression-coping-for-closed-tray-multi-unit-level-non-positioned-narrow","provider":"BIONIKA Webshop","version":"1.0","type":"link"}